![ASTRO ATS-9800 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/astro/ats-9800/ats-9800_operators-manual_2990993013.webp)
SECTION 2
ASSEMBLY
13
External Feeder Control Setup
CAUTION
THIS PROCESS SHOULD BE PERFORMED BY A QUALIFIED SERVICE
PERSON. PLEASE CONTACT YOUR LOCAL DEALER FOR
TECHNICAL HELP.
INFORMATION PROVIDED IN THIS SECTION IS FOR USE BY THE
SERVICE TECHNICIAN.
WARNING
BEFORE PERFORMING THIS TASK, DISCONNNECT THE TABBER
FROM ITS POWER SOURCE!
Transport Stop Delay Feature:
Allows the Tabber to continue to cycle the Transport System for a few seconds, before
the Tabber Transport stops. When used with an external Feeder; this feature is useful to
clear the Tabber of material before it stops.
x
When the Feed Button is pressed to start the system:
Tabber Transport
System is engaged. At the same time, the Tabber sends a signal to the external
Feeder to start the Feeder.
x
When the Feed Button is pressed again to stop the system:
Tabber sends
a signal to stop the Feeder, but the Tabber Transport continues to cycle for a
few additional seconds. This clears the Tabber of all media before it stops.
To enable the Transport Stop Delay feature:
Jumper J7 must be removed from the
Main PCB of the Tabber. Keep the Jumper in a safe place for possible future use.
To disable the Transport Stop Delay feature:
Jumper J7 must be installed on the
Main PCB of the Tabber.
Remove Control Panel Cover (
2 top screws, 2 bottom screws
) to access the Main PCB.
Jumper J7 installed = "stand-
alone" mode
(no delay in Tabber
Transport stop.)
Jumper J7 removed = "in-line"
mode
(3 second delay in Tabber
Transport stop.)