MAINTENANCE
74
Tab Sensor Test
Use
"V-Tab adjustment"
screen to check live tab sensor voltage (V=) value.
1.
Not Interrupted
(
Nothing in Sensor, Tab stock removed
.)
=
0.12V or less.
2.
Tab Sensor reads higher than 0.12V,
even though you removed all tab material
from Tab Applicator and cleaned Tab Sensor: indicates a dirty or damaged Sensor.
3.
Tab Sensor reads 3.30V or higher,
even when Sensor is not interrupted: indicates a
totally blocked, damaged, or disconnected Sensor.
4.
Tab Sensor does not respond correctly after being cleaned,
a qualified service
person should be contacted to disassemble, clean and possibly replace Tab Sensor.
Cleaning Tab Wrap Guides
Each Transport Belt assembly has a Tab Guide that helps to fold tab over for sealing by Pressure
Rollers. While running, a buildup of adhesive will restrict tab from going into Guide. Both of the
Guides and slots should be periodically cleaned with a Q-tip saturated with WD-40 to remove
adhesive residue and provide some lubrication.