PROGRAMMING THE TABBER
55
3.
Before setting up job, set up Tabber
Sensors to read stamp. Select
V-Tab
and follow instructions.
4.
Next screen allows you to select Head
you are using to tab. (
This example
uses Head 1, so select
V-Tab 1
.)
5.
To manually program V Tab
voltage:
Begin by finding Gap V (
or
voltage return from space between
Stamps in this case
.) Release Hold
Down Roller Latch so stamps can
slide easily through Sensor. Move
Stamp web through Sensor until you
obtain lowest voltage reading , then
press
Gap V
key (1). Continue moving Stamp web through Sensor until you obtain
highest reading, then press
Tab V
key (2). When you are finished, press
BACK
key (3).
NOTE: When setting Gap Voltage and Tab Voltage manually, software determines if
Tab Type is Opaque or Clear based on voltage readings.
6.
From
“
Select Setup Option
”
screen,
select
Manual
.
Tab Type
Description
Gap V Level
Tab V Level
Opaque
Tabs in which space between tabs is lighter
than tab even if tab is white.
Low
High
Clear
Tabs that have a black line between tabs.
High
Low
Содержание ATS-309
Страница 1: ...ASTRO ATS 309 MULTI TABBER STAMP AFFIXER OPERATOR MANUAL ...
Страница 90: ...APPENDIX 86 TABBER SETUP 1 JOB TEMPLATES ...
Страница 91: ...APPENDIX 87 TABBER SETUP 2 JOB TEMPLATES ...
Страница 92: ...APPENDIX 88 TABBER SETUP 3 JOB TEMPLATES ...
Страница 93: ...APPENDIX 89 TABBER SETUP 4 JOB TEMPLATES ...
Страница 94: ...APPENDIX 90 TABBER SETUP 5 JOB TEMPLATES ...
Страница 98: ......
Страница 99: ......
Страница 100: ...Copyright 2015 All rights reserved 05 20 2015 Part Number 100 ATS 309 Rev G ...