![ASTRO ATS-309 Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/astro/ats-309/ats-309_operators-manual_2990991064.webp)
PROGRAMMING THE TABBER
60
1.
Begin by selecting
Job #
from
“
Press Run to tab
”
screen.
2.
Then select
Job #
3
from
“
Select saved
Job#
”
screen.
3.
Before you can set up job you must set
up Tabber Sensors to read tab. Select
V-Tab
and follow instructions.
4.
Next screen allows you to select Head
that you are using to tab. In this case, we
are using Head 2, so select
V-Tab 2
.
5.
To manually program V Tab voltage:
Begin by finding Gap V (
or voltage
return from space between stamps in
this case
.) Release Hold Down Roller
Latch so stamps can slide easily through
Sensor. Move stamp web through
Sensor until you obtain lowest voltage
reading , then press
Gap V
key (1).
Continue moving stamp web through Sensor until you obtain highest reading, then press
Tab V
key (2). When finished, press
BACK
key (3) until you return to
“
Select Setup
Option
”
screen.