2.4.4.2.7.2
XPORT REMOTE HOST SETUP
In order to use Remote Host you must follow the steps below...
1.
The 'Remote Host' option must be enabled in the firmware of the desired system/s.
2.
If you already have an existing Traka system/s with previously configured XPorts, then you will need to
change the Connect Mode of the XPort.
To change the Connect mode, from the Traka32 software select Engineers>Diagnostics. From the
Diagnostics window select the XPort Utilities tab and click the Search button. A list of active XPort devices
will be displayed along with the MAC address of each XPort and the device's IP address.
3.
Locate your XPort device either by the MAC Address or the IP address, then click it once to highlight it and
select the Telnet button. You will notice on the right hand side of the screen that you have connected to the
XPort. You will be prompted to press the Enter button. Next press the number 1 button and then the Enter
button. You are now in the 'Channel 1' setup menu. Press the Enter button until you get to the 'Connect
Mode'.
The 'Connect Mode' will be set up as C0 and needs to be changed to D7. Simply enter D7 and select Enter.
4.
Enable remote host comms type in File>Properties>Comms>Remote Host (interval is optional, and is not
for remote host, only for standard autocomms).
5.
Right click on the Control Panel and select Configure system>Comms, and then tick the 'Include in
autocomms' option.
6.
Click Save & Close and then close and re-open Traka32.
Содержание TRAKA32
Страница 220: ...V3 5 14 08 19 UD0089 Page 220 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 482: ...V3 5 14 08 19 UD0089 Page 482 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 587: ...V3 5 14 08 19 UD0089 Page 587 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 723: ...V3 5 14 08 19 UD0089 Page 723 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 748: ...V3 5 14 08 19 UD0089 Page 748 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 771: ...V3 5 14 08 19 UD0089 Page 771 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 796: ...V3 5 14 08 19 UD0089 Page 796 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 856: ...V3 5 14 08 19 UD0089 Page 856 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 857: ...V3 5 14 08 19 UD0089 Page 857 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 866: ...V3 5 14 08 19 UD0089 Page 866 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT Version 1 2 0 green ...
Страница 871: ...V3 5 14 08 19 UD0089 Page 871 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT RS 485 ...
Страница 895: ...V3 5 14 08 19 UD0089 Page 895 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...
Страница 906: ...V3 5 14 08 19 UD0089 Page 906 This Document is uncontrolled unless over stamped CONTROLLED DOCUMENT ...