700002-Rev N 09/18
®
5800 ADAEZ PRO
Installation and Operation Instructions
14 of 50
WHEN STOP IS LESS THAN 1-1/2”
WIDE - MOUNT PIVOT BRACKET TO
THE FACE OF THE RABBET
STOP LESS THAN 1-1/2”
Operator And Door Arm Installation Instructions - Push Side Applications
6
Determining the Door Arm Pivot Bracket Mounting Location.
Figure 9
STOP GREATER
THAN 1-1/2”
WHEN STOP IS GREATER THAN 1-1/2”
WIDE - MOUNT PIVOT BRACKET TO
THE FACE OF THE STOP
Determine the mounting location of the triangular vertical support bracket
STOP GREATER
THAN 1-1/2”
5/8” MINIMUM
1-1/2” MAXIMUM
5/8” MINIMUM
1-1/2” MAXIMUM
5/8” MINIMUM
1-1/2” MAXIMUM
Figure 10
DOOR
DOOR
DOOR
TRIANGULAR VERTICAL
SUPPORT POSITION 2
TRIANGULAR VERTICAL
SUPPORT NOT USED
TRIANGULAR VERTICAL
SUPPORT POSITION 1
DOOR
DOOR