700002-Rev N 09/18
®
5800 ADAEZ PRO
Installation and Operation Instructions
49 of 50
Attachments
A
3. ADAEZ Installation Schematics
(Sheet 6 of 6)
System Description:
• Operator is activated by Wave to Open Switch
• Door initiates an automatic open cycle
System Requirements:
• ADAEZ with Wave to Open switches (p/n
5845xWTO)
• ADA1028W Wireless Interface Module
• Wireless Interface Module unlocks electric lock
ADAEZ PRO with 700 series Wave-to-Open activation switches AND Electric Lock
Figure 42
WAVE TO
OPEN SWITCH
(BACK)
ADA1015P HARDWIRE
KIT (INCLUDED)
WAVE TO
OPEN SWITCH
(BACK)
INSIDE
BUTTON
INSIDE BUTTON
PRESS & RELEASE
TO LEARN
HOLD TO ERASE
OUTSIDE
BUTTON
DOOR
OPERATOR
FIRE P
ANEL
IN COM OUT
A
CCESS CTR
OUTSIDE BUTT
ON
DISABLE
LOCK
PO
WER
NO COM NC
LOCK
OUTSIDE BUTTON
PRESS & RELEASE
TO LEARN
HOLD TO ERASE
OPERATOR
SIGNAL
SIGNAL
DELAY
POWER IN
12 OR 24V
+
CH S
LOCK
POWER
SUPPLY
FAIL SECURE
FAIL SAFE
+
CH S
BLACK WIRE
BLACK WIRE
W/ WHITE STRIPE
ADA1028W WIRELESS
INTERFACE MODULE
(NOT INCLUDED)
BLA
CK
WIRE
BLA
CK
WIRE
W/
WHITE STRIPE
Power +
N/C
C
N/O
Power -
Power +
N/C
C
N/O
Power -
BLACK WIRE
BLACK WIRE
W/ WHITE STRIPE