700002-Rev N 09/18
®
5800 ADAEZ PRO
Installation and Operation Instructions
45 of 50
Attachments
A
3. ADAEZ Installation Schematics
(Sheet 2 of 6)
• ADAEZ Hardwired kit (p/n ADA1015P) is
REQUIRED.
System Description:
• 1x ADA1028W Wireless Interface Module
• 1x ADA1012-2 – Rectangular Pushbutton with
RF transmitter
• Access Control BY OTHERS
System Requirements:
• A valid card presented to the reader will unlock
the door and initiate an automatic open cycle.
• Inside pushbutton is always enabled.
ADAEZ PRO PLUS with Electric Lock and Access Control Panel - No Outside Button
INSIDE
BUTTON
INSIDE BUTTON
PRESS & RELEASE
TO LEARN
HOLD TO ERASE
OUTSIDE
BUTTON
DOOR
OPERATOR
FIRE P
ANEL
IN COM OUT
A
CCESS CTR
OUTSIDE BUTT
ON
DISABLE
LOCK
PO
WER
NO COM NC
LOCK
OUTSIDE BUTTON
PRESS & RELEASE
TO LEARN
HOLD TO ERASE
OPERATOR
SIGNAL
SIGNAL
DELAY
POWER IN
12 OR 24V
+
CH S
LOCK
POWER
SUPPLY
FAIL SECURE
FAIL SAFE
ALARM
PANEL
CARD READER
(ACCESS
CONTROL)
+
CH S
Inside Wireless
Pushbutton
Figure 38