CONFIG Menu
The CONFIG menu is used to set numerous product settings. They are stored in flash memory and so
will be retained between power cycles and when batteries are removed.
Keys operate as follows:
LEFT
and
RIGHT
Navigate through the option fields.
UP
and
DOWN
Select the required value within an option field.
ENTER
Not used.
FUNCT
Not used.
USER
3 second press to add or remove this menu from the shortcut list.
The option fields function as follows:
VERSION
Firmware revision, read only.
BOOT COUNT
Number of times the product has been booted.
USER NAME
Enter user / owner name. This will be displayed on boot splash screen. Warning:
once set this cannot be changed.
USER CO
Enter user / owner company. This will be displayed on boot splash screen.
Warning: once set this cannot be changed.
ST’BY TIME
The time in minutes, that Commissioner will wait after any key press before
powering off. The standby timer is inhibited when USB power is connected. Set a
value of zero to disable the standby timer. Maximum value is 240 minutes.
Default is 10 minutes.
USB VOLTS
The USB port is used to power Commissioner and also recharge the batteries.
When USB is disconnected this field shows ‘Off’. When connected it shows the
USB volage. A value in the range 4800mV
–
5200mV is normal.
BAT VOLTS
Voltage measured at the battery terminals. Fully charged, new batteries will read
approximately 2500mV.
BAT REMAIN
Estimated charge remaining in batteries.
Config
Version
V1.3
Содержание Commissioner rdmx
Страница 1: ...Commissioner rdmx User Guide Artistic Licence Engineering Ltd Firmware v1 3 User Guide v2 0 ...
Страница 2: ...2 ...
Страница 5: ...5 Waste Electrical Electronic Equipment WEEE 47 ...
Страница 6: ...6 ...
Страница 41: ...41 Data cores swapped Broken ground screen Double End 1 1 2 3 3 2 Double End 1 2 2 3 3 ...