30
Commissioner gets the parameter and displays it in the DATA field. In
this example a start address of 009.
Get the start address of the second root device
Use the LEFT, RIGHT, UP, DOWN keys to set the device to 002 and sub-
device to 000, shown in green. This is the second sunDial’s root device.
Use the LEFT, RIGHT, UP, DOWN keys to set the PARAMETER to START
ADDR.
Commissioner gets the parameter and displays it in the DATA field. In
this example a start address of 005.
Get the footprint
of the second device’s second sub
-device
Use the LEFT, RIGHT, UP, DOWN keys to set the device to 002 and sub-
device to 002
, shown in green. This is the second sunDial’s second
sub-device.
Use the LEFT, RIGHT, UP, DOWN keys to set the PARAMETER to
FOOTPRINT.
Commissioner gets the parameter and displays it in the DATA field. In
this example a footprint is 001 as this is a sub-device controlling a
single dimmer channel.
Set the start address of the first root device
Use the LEFT, RIGHT, UP, DOWN keys to set the device to 001, shown
in green. This is the first sunDial.
Use the LEFT, RIGHT, UP, DOWN keys to set the sub-device to 000,
shown in blue. This means the root device is being accessed.
Change the start address to the desired value (value 050 shown in
green) and press ENTER.
Dv
001
-
000
START ADDR
009
Enter = Go
Dv
001
-
000
START ADDR
005
Enter = Go
Dv
001
-
000
START ADDR
050
Enter = Go
Dv
002
-
000
START ADDR
005
Enter = Go
Dv
002
-
000
START ADDR
005
Enter = Go
Dv
002
-
002
FOOTPRINT
001
Dv
002
-
002
FOOTPRINT
001