13
RGBW
Each group of four channels in the selected range is treated as RGBW and cycled through
primary and then secondary colour mixes.
To change the operating function either press the FUNCT key or select the Func field and use the UP
and DOWN keys.
When would I use this?
If you need to go to the stage or outside a building to check lamps, this menu allows an
automatically changing test pattern to be transmitted. Hint: Check the Standby Timer to ensure
Commissioner does not power down when you are away!
DMX
–
TRANSMIT - SCENE Menu
The DMX-TRANSMIT-SCENE menu is used to playback and edit any of the forty scenes. The scenes
are saved in flash memory and so will be available between power cycles and even when batteries
are removed.
Keys operate as follows:
LEFT
and
RIGHT
Navigate through the option fields. In the product, option fields are shown in
UPPER CASE. In this guide, option fields are highlighted in red.
UP
and
DOWN
Select the required value within an option field.
ENTER
Toggle the level of the selected channel.
FUNCT
Not used.
USER
3 second press to add or remove this menu from the shortcut list.
The fields are:
Scene
Select one of the forty scenes. Each scene contains a full 512 channel set of levels.
Chan
The channel to be edited.
At
Level of the selected channel to be set. ENTER is used to toggle the selected level.
The bottom line of the display provides a bargraph mimic of the scene’s levels, fr
om the selected
channel.
When would I use this?
As each scene holds individual levels for every channel, scenes are a great way to setup show
specific test panels for lamp checking.
Scene
39
Chan
001
at
255
/255