28
UP
and
DOWN
Select the required value within an option field.
FUNCT
Turns identify on or off for the selected devices.
ENTER
Not used.
USER
3 second press to add or remove this menu from the shortcut list.
The option fields function as follows:
DEV
Selects the RDM device. Devices are numbered from 1. A value of zero is displayed as ALL
and indicates that all RDM devices are being controlled. This is a very powerful feature but
should be treated with caution as it allows, for example, all start addresses to be set to the
same value. NB. The device number is enumerated during discovery and numbers are
allocated in the order in which devices are discovered. The order may change when
discovery is next executed.
SUB
Selects the sub-device. An RDM device may have a number of sub-devices and
Commissioner is able to access 999 sub-devices. There are two special cases of sub-device.
Zero accesses the root device. ALL indicates that all sub-devices are being controlled.
NAME
When an individual device or sub-device is addressed, the name of the device or sub-
device is displayed here. If ALL devices and/or ALL sub-devices is selected, BROADCAST is
displayed.
The following example shows how this is used. We are connected to an Artistic Licence sunDial
dimmer.
Get the status messages from the first root device
Use the LEFT, RIGHT, UP, DOWN keys to set the device to 001.
In this example the device, a sunDial, has a critical Over
Temperature message.
When would I use this?
When a particular device is suspected of a fault, this allows you to continuously monitor for fault
reports.
DMX
–
RDM
–
GET+SET Menu
DMX-RDM-GET+SET is used to get or set RDM parameters. It is only possible to get a parameter from
a unique device or sub-device. However, any range of devices and sub-devices can have parameters
set using broadcasting (as described below).
Keys operate as follows:
Dv
DEV
-
SUB
name
Message
Dv 001-000
sunDial 1
Over Temp