Ankara 4P - Arka 4P
English
05060215 00 05-2022
50
The engine is
noisy
•
screws and bolts are not tight
-
ened
•
tighten the bolts and screws
•
the cabinet is not levelled
•
level the counter
Condensate
•
poor room conditions
•
check the position of the counter inside the
store
•
poor air ventilation
•
check the operation of fans and wiring
•
If present, the heating elements
of the glass panels do not work
•
check electrical connections
•
check the operation of heating elements
•
the windows are not closed
properly
•
close the windows properly
The tempera-
ture of the
cabinet is too
high or too
low
•
poor room conditions
•
check the position of the counter inside the
store
•
output air temperature is out
-
side the specified range
•
check the operation of evaporator fan
•
check wiring and input voltage
•
the fans are installed reversely; check and re
-
store the air flow direction
•
check that fan plenum is sufficient and not
obstructed
•
check the intake pressure that should comply
with rated specifications
•
the cabinet is defrosting.
•
check defrosting parameters
•
the capacitor or the evaporator
are freezing.
•
check that the suction line is not obstructed
•
the capacitor or the evaporator
are obstructed or dirty.
•
proceed with cleaning chap.23.4
•
the load is not distributed even
-
ly
•
load the goods in an orderly fashion (Fig.13)
Water leaks,
bad smell
•
The cabinet drains are blocked
or damaged
•
free the drain
•
repair or replace the drains
•
water collection tray is sealed
incorrectly
•
seal it properly
•
water collection tray overflows
•
check wiring of evaporation heater
•
check the operation of evaporation heater
•
insufficient joints between cabi
-
nets in channel or joints not
sealed correctly
•
install and seal the joints
Frost or ice
in the cabinet
•
fans do not work
in the evaporator
•
heating elements broken
•
Sdef probe detached
•
check electrical connections
•
check the defrost parameters on the control
-
ler
•
air currents that alter the circu
-
lation of refrigerated air
•
check the ventilation inside the store
i
in all cases not described or where it is not possible to solve the problem by following these
directions call the nearest authorised after-sales centre.
29. Assembly instructions
i
the assembly instructions, after registration, are available at this address:
https://globalassistance.arneg.it/.