Ankara 4P - Arka 4P
English
05060215 00 05-2022
38
Climatic Class of the
testing chamber
Temperature
dry bulb
Relative
Humidity
Dew
point
Weight of water
vapour in dry air
°C
%
°C
g/kg
0
20
50
9.3
7.3
1
16
80
12.6
9.1
2
22
65
15.2
10.8
3
25
60
16.7
12.0
4
30
55
20.0
14.8
6
27
70
21.1
15.8
5
40
40
23.9
18.8
7
35
75
30.0
27.3
8
23.9
55
14.3
10.2
The mass of water vapour in dry air is one of the main elements that affect the performance and
power consumption of the cabinets. The safety test is carried out in accordance with standards
IEC
EN 60335-2-89
at an ambient temperature of 32°C +/-2°C.
Declaration of
conformity
A copy of the declaration of conformity is attached to the cabinet.
If the original copy of the Declaration of Conformity supplied with the unit is
lost, download a copy by filling out the form found in the footer of the home
page of the website
www.arneg.it
under "
EU compliance
”.
10. Identification - Rating Plate
The serial plate containing all technical specifications (Fig.2) is affixed to the side of the cabinet:
N°
Name
1
place/name of the manufacturer
2
name and length of the cabinet
3
code of the cabinet
4
serial number of the cabinet
5
supply voltage
6
operating electrical power absorbed in the defrosting phase
(armoured hot wires+ fans+lighting)
7
usable display surface
8
type of refrigerant fluid used by the system to operate
9
environmental climatic class and temperature of reference
10
number of the job order based on which the cabinet has been manufactured
11
number of purchase order based on which the cabinet has been put in production
12
year of manufacture of the cabinet
13
EAC marking
14
operation class
15
weight of refrigerant gas loaded in every system
(only for cabinets with a built-in motor)
16
heating capacity
17
lighting power (where included)
18 class of protection against humidity
19
QR code
20
operating current consumption
21
operating electrical power absorbed in the refrigeration phase
(fans+hot wires+lighting)
22
Power supply frequency
i
For assistance, give the manufacturer the following information:
-
the product name (2); the serial number (4); the job order number (10)
NEVER
remove the serial number plate under any circumstances