Ankara 4P - Arka 4P
English
05060215 00 05-2022
49
•
to carefully and continually carry out maintenance operations
•
authorises the use of the machine by operators and technicians trained for the purpose and with
proven skills and behaviour (see chap.4-5-6)
Conditions
Italy
: unless otherwise agreed, the machines are guaranteed only if factory
new, for one year from the date of shipment, except for the electrical and
related parts. Within this period, the parts will be replaced or repaired for free
at the discretion of our technicians that will assess it they are defective. For
further details on warranty conditions please check the sales terms.
Overseas
: see the agreements with the respective dealers or area managers.
i
Failure to comply with the instructions in this manual shall void the warranty.
27. Spare parts
Use only original spare parts
•
replace the parts before wearing excessively to avoid damage to persons or property
•
carry out scheduled maintenance as provided in the agreement
The spare parts catalogue can be found at this address: https://globalassistance.arneg.it/
28. Troubleshooting
DANGER! Live parts. Electrocution.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
Problem
Possible causes
Possible solutions
The cabinet
stops or does
not start
•
power black-out
•
check the cause of the black-out
•
master switch turned off
•
turn on the switch
•
breakers triggered (fuses,
thermal breakers/differential
switches)
•
check the temperature of the condensing
unit
•
electronic controller faulty
•
repair/replace the controller
once the electrical supply has been restored, check that all the electrical
equipment in the store will restart without triggering the overload protec
-
tion devices; otherwise, modify the system to differentiate the start-up of
the various devices
i
If power is not restored in a short time, store the goods in a cold room to
maintain the storage temperature.
The cabinet
does not
cool
sufficiently
•
the cabinet is in the defrosting
phase
•
wait for defrost to finish (~ 30min)
•
air inlets are obstructed
•
release air inlets
•
the load is not distributed even
-
ly
•
load the goods in an orderly fashion (Fig.13)
•
the capacitor is dirty
•
clean the capacitor chap.23.4
•
the cabinet is next to air cur
-
rents or heat sources
•
check the position of the cabinet inside the
store
•
the cabinet is not levelled
•
level the counter