MAGB2 User Guide
39
V1.7 2021-10-01
11.13. GPRS settings
Modbus
register
Modbus
address
Data type
No. of
decimal
Min
Value
Max Value
Description
Read/
Write
5000
4999
Longint
0
0
99999
Interval
R/W
5002
5001
Longint
0
0
24
Start hour
R/W
5004
5003
Longint
-
0
3
Automatic sending,
0=OFF, 1=TCP only,
2=SMS pmůy, 3=TCP and
SMS
R/W
5006
5005
*
-
-
-
Server IP
5008
5007
Longint
0
0
99999
Server port
R/W
5010
5009
*
-
-
-
SIM APN
5012
5011
*
-
-
-
SMS phone 1
5014
5013
*
-
-
-
SMS phone 2
5016
5015
*
-
-
-
SMS phone 3
5018
5017
Longint
0
0
Device ID
R/W
5020
5019
Bool
0
0
1
SMS Format, 0=Default,
1=NMX
R/W
5022
5021
*
-
-
-
NMX RFC
5024
5023
Longint
5
-
9999999
9
99999999 Latitude
R/W
5026
5025
Longint
5
-
9999999
9
99999999 Longitude
R/W
5028
5027
Longint
0
0
999
UV
R/W
5030
5029
Bool
-
0
1
Send GPRS message
R/W
5032
5031
Bool
-
0
1
Send SMS
R/W
*subject to development of the string mode of MODBUS. So far to be set via keyboard.
Interval
– sets interval between messages.
Start hour
– sets at which hour the interval starts.
Automatic sending
– if set to on the meter sends messages automatically to server/phone based on
interval and start hour.
Server IP
– sets server IP address where the data goes.
Server port
– sets server TCP port where the data goes.
SIM APN
– sets the APN of the SIM card – check with SIM card provider.
SMS phone 1, SMS phone 2, SMS phone 3
– sets up to 3 phone numbers to send the messages to.
Device ID
– Used for Arkon.Track.
SMS Format
– format of the SMS message – specific to some countries
NMX RFC, UV
– country specific
Latitude, Longitude
– place of meter installation
Send GPRS message
–
sends one TCP message to server
– used for testing purposes.
Содержание MAGB2
Страница 1: ......
Страница 10: ...MAGB2 User Guide 9 V1 7 2021 10 01 2 6 Connections overview ...
Страница 13: ...MAGB2 User Guide 12 V1 7 2021 10 01 GPRS module connected Excitation failed 4 20mA module connected ...
Страница 49: ...MAGB2 User Guide 48 V1 7 2021 10 01 17 Flowmeter Dimensions Compact version Remote version ...