MAGB2 User Guide
17
V1.7 2021-10-01
8. External measurements
Two different sensors can be connected to MAGB2 flowmeter
– low power temperature and/or low power
pressure sensor. The needed tool is flat head screwdriver 2mm.
8.1. External temperature sensor
A special low power smart temperature sensor is used.
Specification:
Range
-20 -
130°C
Ambient temperature -20 -
130°C
Power supply
3,3VDC
Output type
Impulse
Accuracy
+-
0,5°C
Process connection
M20x1,5 male
Ingress protection
IP67
Cable legth
1 meter
Excitation frequency
1,5; 1/5; 1/15; 1/30
MAGB2 connection:
Mechanical connection:
The preload is 20Nm.
The installation torque is 34 Nm.
The maximum installation torque shall not exceed 70 Nm.
Sealing: O ring D
17x2.5, NBR70°