Revised by R. Robinson
Issue AV1.13 8 June 2006
14
Zone 125
Busy Tn On1 Time
Default value =
025
Range =
(000 ~ 255) *20 mSec.
and
define the carrier’s busy tone cycle so the system can recognize busy tone.
the duration of tone on and
is the duration of silence in the cycle.
Related Zones.
,
,
Zone 126
Busy Tn Off1 Time
Default value =
025
Range =
(000 ~ 255) *20 mSec.
and
define the carrier’s busy tone cycle so the system can recognize busy tone.
the duration of tone on and
is the duration of silence in the cycle.
Related Zones.
,
,
Zone 127
Busy Tn On2 Time
Default value =
012
Range =
(000 ~ 255) *20 mSec.
and
define a second example of the carrier’s busy tone cycle so the system can recognize
is the duration of tone on and
is the duration of silence in the cycle.
Related Zones.
,
,
Zone 128
Busy Tn Off2 Time
Default value =
012
Range =
(000 ~ 255) *20 mSec.
and
define a second example of the carrier’s busy tone cycle so the system can recognize
is the duration of tone on and
is the duration of silence in the cycle.
Related Zones.
,
,
Zone 129
Swon Delay Time
Default value =
003
Range =
(000 ~ 255) *40 mSec.
This timer is the duration taken by the system to make the connection of an extension to a C.O. line when a
C.O. line is selected. Any digits dialed during this period may be lost. For an SLT, this may mean
malfunctioning of the redial facility.
NOTE! THIS MUST NOT BE 000 IF LCR IS PROGRAMMED. IF LCR IS IN USE ZONE 219 MUST
BE A NON-ZERO VALUE
Related Zones.
Zone 130
Co Delay Tm
Default value =
001
Range =
(000 ~ 255) *1 Sec.
This timer inhibits re-selecting a C.O. line, for the set time, after it has been released from an outgoing call.
Ie.: prevents “follow on” calls.
Related Zones.
Zone 131
Door SensorD
Default value =
000
Range =
(000 ~ 255) *1 Sec.
Stations will not ring when the Door Sensor has been activated, until this time has been reached.
Related Zones.