138
Stator Coil
VOLTAGE (AC Generator - Regulated
Output)
1. Set the meter selector to the DC Voltage position.
2. Connect the red tester lead to the positive battery
post; then connect the black tester lead to the nega-
tive battery post.
3. With the vehicle in neutral and the engine running as
shown in the chart (with the headlights on), the meter
must show 14-15.5 DC volts.
NOTE: If voltage is lower than specified, test AC
Generator - No Load.
VOLTAGE (AC Generator - No Load)
The connector is the black three-pin one on the right side
below the ignition coil.
HDX150A
NOTE: Test the connector coming from the
engine.
1. Set the meter selector to the AC Voltage position.
2. Test between the three yellow wires for a total of
three tests.
3. With the engine running at a constant 5000 RPM, all
wire tests must be within specification
NOTE: If both stator coil tests failed, check all
connections, etc., and test again. If no voltage is
present, replace the stator coil assembly.
RESISTANCE (AC Generator)
1. Set the meter selector to OHMS position.
2. Test between the three yellow wires for a total of
three tests.
3. The meter reading must be within specification.
Starter Motor
NOTE: The starter motor is not a serviceable
component. If the starter is defective, it must be
replaced.
REMOVING
1. Disconnect the battery.
2. Remove the nut securing the positive cable to the starter;
then remove the cable from the starter.
3. Remove the two cap screws securing the starter with
ground wires to the crankcase; then remove the starter.
Account for the wiring forms and an O-ring.
INSTALLING
1. Apply a small amount of grease to the O-ring seal on the
starter; then install the starter into the crankcase. Secure
with two machine screws and wiring forms.
2. Secure the positive cable to the starter with the nut.
3. Connect the battery.
TESTING VOLTAGE
Perform this test on the starter positive terminal. To access
the terminal, slide the boot away.
NOTE: The ignition switch must be in the ON posi-
tion, and the shift lever in the NEUTRAL position.
1. Set the meter selector to the DC Voltage position.
2. Connect the red tester lead to the starter terminal; then
connect the black tester lead to ground.
3. With the starter button depressed, the meter must show
battery voltage and the starter should operate.
MODEL
RPM
500
3000
700
5000
CAUTION
Do not run the engine at high RPM for more than 10 sec-
onds.
CAUTION
Do not run the engine at high RPM for more than 10 sec-
onds.
CAUTION
Always disconnect the battery when performing resis-
tance tests to avoid damaging the multimeter.
CAUTION
Always disconnect the negative battery cable from the
battery first; then disconnect the positive cable.