5-7
5
1411-576
1411-526
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to one spade end of the
fuse; then connect the black tester lead to the other
spade end.
3. The meter must show less than 1 ohm resistance.
If the meter shows open, replace the fuse.
NOTE: Make sure the fuses are returned to their
proper position according to amperage. Refer to
the amperage listed under each fuse on the power
distribution module.
RELAYS
The relays are indentical plug-in type located on the
power distribution module. Relay function can be
checked by switching relay positions. The relays are
interchangeable.
NOTE: The module and wiring harness are not a
serviceable component and must be replaced as
an assembly.
Ignition Coil
The ignition coil is mounted on the fuel pump mount-
ing plate adjacent to the fuel pump.
VOLTAGE (Primary Side)
See PEAK VOLTAGE Primary Coil (650 cc) or Pri-
mary Coil (550/700 cc) in this sub-section.
RESISTANCE
NOTE: For these tests, the meter selector should
be set to the OHMS position.
Primary Winding
1. Connect the red tester lead to the terminal (with
the wire removed); then connect the black tester
lead to ground.
PR278A
2. The meter reading must be within specification.
Secondary Winding
1. Connect the red tester lead to the high tension lead
(with the plug cap removed); then connect the
black tester lead to ground.
2. The meter reading must be within specification.
NOTE: If the meter does not show as specified,
replace ignition coil.
Spark Plug Cap
1. Connect the red tester lead to one end of the cap;
then connect the black tester lead to the other end
of the cap.
550/650 cc
700 cc
! CAUTION
Always replace a blown fuse with a fuse of the same
type and rating.
! CAUTION
Always disconnect the battery when performing
resistance tests to avoid damaging the multimeter.
! CAUTION
Always disconnect the battery when performing
resistance tests to avoid damaging the multimeter.
Back to TOC
Back to Section TOC
Next
Back