52
1201 Utility Software
7.13.5
Pulse Per Day Mode
Choose this programmable pulse mode to provide a pulse every day at the chosen hour, minute,
second and fractional seconds. Configure the pulse width, from 10 milliseconds to 600 seconds.
Check jumpers in Table 5.1.
Figure 7.15: Programmable Pulse, Pulse Per Day Screen
7.13.6
Single Trigger Mode
Choose this programmable pulse mode to provide a pulse every year at the chosen Julian Day of
year, hour, minute, second and fractional seconds. Single Trigger polarity may start as either high
(positive) or low (negative). When the trigger occurs, it transitions to the opposite polarity and
remains at that value until Single Trigger is deliberately reset. Check jumpers in Table 5.1.
Figure 7.16: Programmable Pulse, Single Trigger Screen