132
Options List
Driver Jumper Position: JMP9 – JMP12
For JMP1 – JMP4 positions 1 and 2 (shown below in Table B.1), jumpers JMP9 – JMP12 should be in
position B. These are used for analog signals. In all other JMP1 – JMP4 positions (i.e. 3 – 20), JMP9 –
JMP12 must be in position A for digital signals. Available signal choices in the Model 1201B/C are marked
in Table B.1 with an asterisk (*).
Position
Analog Signals
Signal Description
1*
IRIG-B
Modulated IRIG-B
2
Deviation
Frequency input – Model 1088B only
Position
Digital Signals
Signal Description
3*
IRIG-B:
IRIG format B time code, unmodulated, one second frame rate.
4
IRIG-E:
IRIG format E time code, modulated or unmodulated, 10 second second
frame rate.
5
IRIG-H:
IRIG format H time code, one minute frame rate.
6
10 MPPS:
10,000,000 pulse-per-second (PPS) square wave, synchronous to the 1 PPS
output.
7
5 MPPS:
5,000,000 PPS square wave, synchronous to the 1 PPS output.
8
1 MPPS:
1,000,000 PPS square wave, synchronous to the 1 PPS output.
9
100 kPPS:
100,000 PPS square wave, synchronous to the 1 PPS output.
10
10 kPPS:
10,000 PPS square wave, synchronous to the 1 PPS output.
11
1 kPPS:
1,000 PPS square wave, synchronous to the 1 PPS output.
12
100 PPS:
100 PPS square wave, synchronous to the 1 PPS output.
13
60 PPS:
60 PPS square wave, synchronous to the 1 PPS output.
14
50 PPS:
50 PPS square wave, synchronous to the 1 PPS output.
15
10 PPS:
10 PPS square wave, synchronous to the 1 PPS output.
16
IRIG-D/1 PPM:
IRIG format D time code (1 pulse per minute), rising edge on time, one hour
frame rate.
17
1 PPH:
1 pulse per hour, rising edge on time.
18*
1 PPS:
(10 ms HI), synchronous to 1 PPS/GNSS
19*
Programmable
Pulse:
Outputs a single pulse at a preprogrammed time, or a continuous pulse train
having a period of one day or less. Pulse width is adjustable from 0.01 to
600 seconds.
20*
Out-of-Lock:
Normally HI after acquisition of satellite signals. Toggles LO nn minutes
after loss of satellite signal lock. Range for nn is 00 to 99 minutes, and is
set using the 1201 Utility software, SETUP menu or RS-232C (refer to clock
Operation Manual). Setting of 00 disables this function (output remains HI).
This output follows the standard Out-of-Lock function on the clock.
21
Spare 1
To be determined.
22
N/A
Not used
Table B.1: Four Configurable Outputs – Signal Choices
Содержание 1201B
Страница 4: ...iv ...
Страница 153: ...B 7 Four Fiber Optic Outputs 135 Figure B 4 Jumper Locations ...
Страница 155: ...B 8 8 Channel High Drive IRIG B Amplifier 137 Figure B 5 8 High Drive Outputs Jumper Locations ...
Страница 171: ...B 10 Four Additional Outputs and Dry Contacts 25 50 Vdc 153 Figure B 7 Option Connector Signal Locations ...
Страница 222: ...Appendix E Statement of Compliance The following page is a statement of compliance that includes Model 1201B and 1201C ...