B.11 NTP/PTP Server
195
•
ntpSysPrecision
: signed integer indicating the precision of the various clocks, in seconds to the
nearest power of two.
•
ntpSysRootDelay
: the total roundtrip delay to the primary reference source at the root of the
synchronization subnet, in seconds.
•
tpSysRootDispersion
: the maximum error relative to the primary reference source at the root of
the synchronization subnet, in seconds. Only positive values greater than zero are possible.
•
ntpSysRefId
: the particular reference clock. In the case of stratum 0 (unspecified) or stratum 1
(primary reference source), this is a pour-octet, left-justified, zero-padded ASCII string. In the case of
stratum 2 and greater (secondary reference) this is the four-octet Internet address of the peer selected
for synchronization.
•
ntpSysRefTime
: the local time when the local clock was last updated. If the local clock as never
been synchronized, the value is zero.
•
ntpSysPoll
: the minimum interval between transmitted messages, in seconds as a power of two. For
instance, a value of six indicates a minimum interval of 64 seconds.
•
ntpSysPeer
: the current synchronization source. Usually this will be a pointer to a structure contain-
ing the peer variables. The special value NULL indicates there is no currently valid synchronization
source.
•
ntpSysPhase
: The system clock offset per selected source. (needs verification)
•
ntpSysFreq
: The system clock frequency correction per ntpd. (needs verification)
•
ntpSysError
: The current system error per ntpd? (needs verification)
•
ntpSysClock
: the current local time. Local time is derived from the hardware clock of the particular
machine and increments at intervals depending on the design used.
•
ntpSysSystem
: the type of local Operating System.
•
ntpSysProcessor
: the type of the local Processor.
Содержание 1201B
Страница 4: ...iv ...
Страница 153: ...B 7 Four Fiber Optic Outputs 135 Figure B 4 Jumper Locations ...
Страница 155: ...B 8 8 Channel High Drive IRIG B Amplifier 137 Figure B 5 8 High Drive Outputs Jumper Locations ...
Страница 171: ...B 10 Four Additional Outputs and Dry Contacts 25 50 Vdc 153 Figure B 7 Option Connector Signal Locations ...
Страница 222: ...Appendix E Statement of Compliance The following page is a statement of compliance that includes Model 1201B and 1201C ...