PDF: 4749051511/Source:7788125767
Aptina reserves the right to change products or specifications without notice.
MT9T111_DG - Rev. B 9/10 EN
83
©2007 Aptina Imaging Corporation. All rights reserved.
MT9T111: Developer Guide
Timing Specifications
Preliminary
Soft Reset
A soft reset sequence to the sensor has the same affect as the hard reset, and can be acti-
vated by writing to a register through the two-wire serial interface. The soft reset signal
sequence is shown in Figure 47, and the soft reset timing is shown in Table 31.
Figure 47:
Soft Reset Signal Sequence
Table 31:
Soft Reset Signal Timing
Parameter
Symbol
Min
Typ
Max
Unit
Active EXTCLK after soft reset command
is asserted
t
1
–
100
–
EXTCLKs
EXTCLK
t1
S
DATA
Mode
Write Soft
Reset Command
Internal Boot
Registers Reset
to Default Values
SCLK