CHAPTER 1
INTRODUCTION
Entire Contents Copyright
2014 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
44M04 LOAD MAINFRAME OPERATIONS MANUAL
Page 12 of 93
44M00
1.3.4
Specifications
Following specifications apply to the 44M04 mainframe.
PARAMETER
PARAMETER
SPECIFICATIONS
SLOTS
Number of Load Modules
Supported
4
AC INPUT
Line Voltage (selectable)
100-115Vac ±10%
200-230Vac ±10%
Frequency
50 / 60 Hz ±3Hz
Fuse
T2A/250V
(5x20 mm)
T1A/250V
(5x20 mm)
Power Consumption
150 Watt Max.
PHYSICAL
Dimensions (H x W x D)
177 x 440 x 445 mm
7.0” x 17.3” x 17.5”
Weight:
9.3 kg
20.5 lbs
ENVIRONMENTAL
Installation Category
Cat I, Pollution Degree 2, Indoor use only
Temperature Range
0 – 40°C
32 – 104°F
Relative Humidity (max.)
80 % non-condensing
Altitude
2000 meters
6000 feet
Table 2: Mainframe Technical Specifications