CHAPTER 4
REMOTE CONTROL PROGRAMMING
Entire Contents Copyright
2014 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
44M04 LOAD MAINFRAME OPERATIONS MANUAL
Page 57 of 93
44M00
1. The time period combines TLOW (time low) and THIGH (time high) sections of a
DYNAMIC waveform.
2. The value of TLOW and THIGH has to be included the number of the decimal point;
otherwise the command will not be available.
3. The least significant number is the fifth after the decimal point.
4. Should a value be entered that is higher than what is possible then the 44M04 will
automatically set its maximum value according the load module fitted.
5. The engineering unit is ms.
LDONv
Command Syntax:
[PRESet
:
] LDONv {SP} {NR2}{
;
| NL}
[PRESet
:
] LDONv?{
;
| NL}
Purpose:
Set and Read the voltage level at which the LOAD will switch ON.
Description:
This command is used to set or query the voltage value at which the LOAD will
automatically switch ON. The engineering unit is V.
LDOFfv
Command Syntax:
[PRESet
:
] LDOFfv {SP} {NR2} {
;
| NL}
[PRESet
:
] LDOFfv?{
;
| NL}
Purpose:
Set and Read the voltage level at which the LOAD will switch OFF.
Description:
This command is used to set or query the voltage value at which the LOAD will
automatically switch OFF. The engineering unit is V.
CURR : HIGH | LOW
Command Syntax:
[PRESet
:
] CC | CURR
:
HIGH | LOW{SP} { NR2}{
; |
NL}
[PRESet
:
] CC | CURR
:
HIGH | LOW? {
; |
NL}
Purpose:
Set or read the HIGH or LOW current levels in Amps.
Description:
This command is used to set or query the HIGH and LOW levels of load current allowed.
These 2 current levels need to be used if a dynamic load waveform is used. It also allows
the user to switch between two preset current levels.