CHAPTER 4
REMOTE CONTROL PROGRAMMING
Entire Contents Copyright
2014 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
44M04 LOAD MAINFRAME OPERATIONS MANUAL
Page 64 of 93
44M00
[PRESet
:
] BW {?} {
;
│NL}
Purpose:
Set and read the BW level to LO or HI.
Description:
The BW command allows the user to change the bandwidth of the 41D/42D series load
when operating in LED mode. The BW Function can be used when in CC Mode, CV
Mode or CR Mode Range I. The initial Value of the bandwidth is HI.
Please note that when operating in CR Mode Range II there is only one bandwidth.
AVG
Command Syntax:
[PRESet
:
] AVG {SP} {n} {
;
│NL}
[PRESet
:
] AVG {?} {
;
│NL}
Purpose:
Set or query the VI Measurement Averaging.
Description:
A number of voltage and current measurements can be averaged. This provides more
stable readings in the presence of noise. The average function can be set in the range from
1 to 64. The default value is one.
LEDNO
Command Syntax:
[PRESet
:
] LEDNO {SP} {n} {
;
│NL}
[PRESet
:
] LEDNO {?} {
;
│NL}
Purpose:
Set or query the quantity of LEDs to simulate.
Description:
This command allows the user to enter or query the total number of LEDs the 41D/42D
series is to simulate.
•
For models 41D3002 and 41D5002 the LEDNO setting range is 1 to 90.
•
For the 41D1020 model the LEDNO setting range is 1 to 30.
•
For the 42D5003 model the LEDNO setting range is 1 to 90.
VO
Command Syntax:
[PRESet
:
]VO {SP} NR2 {
;
│NL}
[PRESet
:
]VO {?}{
;
│NL}
Purpose:
Set and read Vo Voltage in LED mode.