4.6.5
MEASUREMENT Commands
Measurement commands allow measurement data for each module to be retrieved.
MEASure:CURRent?
Command Syntax:
MEASure:CURRent? {; | NL}
Purpose:
Measures the load current.
Description:
Reads the current meter data. The engineering unit is Ampere (A).
MEASure:VOLtage?
Command Syntax:
MEASure:VOLtage? {; | NL}
Purpose:
Measures the load voltage.
Description:
Reads the voltmeter data. The engineering unit is Voltage (V).
MEASure:POWer?
Command Syntax:
MEASure:POWer? {; | NL}
Purpose:
Reads the power being absorbed by the load.
Description:
Reads the power meter data. The engineering unit is Watt (W).
MEASure:VC?
Command Syntax:
MEASure:VC? {; | NL}
Purpose:
Reads the voltage and current being taken by the load.
Description:
Reads the voltage and current meter. Return data format:”###.####,###.####”. The first
value is the Voltage (V), the second value is the Current (A).