Portable Test Equipment
User’s Guide
PTE-UGFW56a-EN
www.appliedp.com
96
MEAS:MAXD:K:TEMP?
Request for actual (temporary) value of Maximum Demand Test.
MEAS:MAXD:WIN:BEG?
Request for timestamp of the beginning of Maximum Demand Test window.
MEAS:MAXD:WIN:END?
Request for duration of Maximum Demand Test window.
MEAS:MAXD:RES
Resets Maximum Demand Test.
MEAS:MAXD:RES?
Request for timestamp of last reset of Maximum Demand Test.
SYST:ASS:STAR
Start of Automatic Snapshots Saving Routine with predefined periodicity.
SYST:ASS:STAR?
Request for status of Automatic Snapshots Saving Routine. Answers are: 0
– not running, 1 –
running.
SYST:ASS:STOP
Cease of Automatic Snapshots Saving Routine.
SYST:ASS:STAT?
Request for number of saved snapshots in currently running Snapshots Saving Routine.
SYST:ASS:MAXC {<x>}
Setting the number (x) of snapshots to be made during Automatic Snapshot Saving Routine.
SYST:ASS:MAXC?
Request for the number of snapshots to be made during Automatic Snapshot Saving Routine.
SYST:ASS:PER {<x>}
Setting the period in minutes (x) of snapshots saving occurrence during Automatic Snapshot Saving
Routine. Minimum value is 0.1 (6s) and maximum is 1440 (24h).
SYST:ASS:PER?
Request for the time period of snapshots saving occurrence during Automatic Snapshot Saving
Routine.
Generator Commands
Generator commands serve for generating load point on the output terminals of PTE.
GEN:STOP
{ [method(0|1|2)] }
Generation stop. Optional parameter
method
specifies transition method: 0 (=default), 1 (=immediate)
or 2(=soft generate). Default transition method (parameter not used or used with value 0) is defined in
menu - Soft Generate ON or OFF.
GEN:STAR?
Request for the actual state of the generation. Answer is 0=off (generation not in progress),
1=transition (transition rise or fall in progress) or 2=on (stable generation in progress). While 1 is
being returned, device is not able to react to new generation commands.
Содержание PTE 2100 Series
Страница 1: ...Portable Test Equipment Models PTE 2100 PTE 2300 User s Guide Version 5 6a ...
Страница 102: ...Portable Test Equipment User s Guide PTE UGFW56a EN www appliedp com 102 7 APPENDIX ...
Страница 104: ...Portable Test Equipment User s Guide PTE UGFW56a EN www appliedp com 104 Figure 22 3P3W Connection with OPTS ...
Страница 105: ...Portable Test Equipment User s Guide www appliedp com PTE UGFW56a EN 105 Figure 23 1P2W Connection with OPTS ...