APPEAR AS
Confidential
83/352
Sequence Protocol
Seamless protocol in use, either
RTP
or
UDP
.
Sequence Errors
Source sequence errors since last reset
Port Status
Either Master or Slave depending on which is the main port
5.4.6.1.1
Unique Configuration of input ports
IP settings can be configured different on the two IP ports in Seamless Input mode. If required to be different
from port A, the checkbox can be enabled and the new parameter entered.
The paramaters presented here are the same as a standard IP Input except for the following:
Filter Input
Syncronisation
This should be enabled on sources that are not syncronised from the same
source.
In this mode, the behavior differs from the Seamless IP mode in that the current
source will switch if there is a 100ms with 0 bitrate on the input multicast.
Override
By default Source B will inherit the same as Source A. If it is required to change
this, you can override each parameter.
5.4.6.1.2
Non-Syncronized Inputs
With the Seamless IP Input module, it is possible to configure two non-syncronized multicasts. In this mode it is
required to enable the ‘Filter input synronization’ option for the port in order to filter the normally present alarm.
In this mode, the behavior differs from the Seamless IP mode in that the current source will switch if there is a
100ms with 0 bitrate on the input multicast.
More details on this can be found in Chapter 12.1.5.