APPEAR AS
Confidential
66/352
5
I
NPUT
C
ONFIGURATION
This chapter describes the
Inputs
node in the GUI and how to analyze the available inputs.
5.1
T
HE
I
NPUTS
N
ODE
The unit can be configured to host a number of different input modules. Open the Inputs node from the
Navigation Pane
to view all available input modules
The following information is available in the
Inputs
node:
Each input module available in the unit has some common analysis features; they all support manual definition of
input PSI. The coming sections will describe these common features followed by details on how each input module
can be configured.
5.2
I
NPUT
A
NALYSIS
For each input module, the unit provides detailed MPEG/DVB/ATSC transport stream analysis for all available
input streams. The following information is provided by the input analysis engine:
•
Port specific status
•
PSI/SI analysis of all input services
Slot
Slot position in the chassis
Type
Type of input module
Services
Number of services present in the transport stream
Input Rate
Seamless IP Input only. Total input rate per port
Eff.Rate
Effective bandwidth of the incoming transport stream
CC Errors
Number of Continuity Counter (CC) errors detected on all input ports since last reset; CC
errors indicate that one or more packets are lost.
Seq Errors
Number of Transport Stream errors detected on all input ports. Errors indicate problems
with the incoming TS structure of the streams
BP Rate
Rate of active services transmitted to the backplane