2.1.1.1
Product models
4RU chassis models: DC1000. DC1001, SC2000, SC2001, MC3000, MC3001 and XC5000
2.1.1.2
Ventilation
The 4RU chassis with Telco mounting has forced air flow from front to back in the chassis, allowing for multiple
units to be stacked above each other with no space in between. However, adequate space must be provided in
front of and behind the unit for effective ventilation. For Broadcast mounting, air flow will be from back to front.
2.1.1.3
Replacing the power supply module
The 4RU chassis can be installed with one or two power supply modules (XC5000 always comes with two power
supply modules). The modules can be exchanged from the rear of the unit. The chassis delivered with a single
power module can be updated by acquiring additional power module.
If power is lost in one of the Power supplies, the other can feed the entire chassis. It is recommended to connect
each input power at different circuits.