APPEAR AS
Confidential
342/352
Port has two options
Ports
The system allows a port to be monitored by only one profile. If a port has been set up for
monitoring in one profile, it will not be available as an option in the other profiles. Writing it
in manually in other profiles nevertheless, the filter will be ignored.
13.2
SNMP
The SNMP agent is located on the MMI module, and uses the same IP address. A number of variables can be
configured, including the SNMP configuration file (containing the public and private community strings, for user
access and alarms); and the trap destination table. This is explained below.
13.2.1
C
ONFIGURATION OF
SNMP
C
OMMUNITY
S
TRINGS IN
GUI
The SNMP Mib Access is configurable in GUI which containing the public and private community strings, for Read
only and Read write community.
13.2.2
C
ONFIGURATION OF
SNMP
H
EARTBEAT RATE IN
GUI
The SNMP heartbeat rate can be enabled in GUI and this trap is sent out every n seconds where n can specified
in the GUI.
13.2.3
C
ONFIGURATION OF
SNMP
A
LARM
F
ILTER VIA THE
GUI
The ordinary alarm filter and the root cause filter is before the SNMP filter, and any alarms which are filtered
away by those mechanisms, and hence are not shown in the active alarm list, are never sent via SNMP.