APPEAR AS
Confidential
121/352
6.3.1.4
Alarm: Stopped descrambling due to rating level
When the rating level in the ECM goes above the value set in the descrambler, the descrambling will stop
and an alarm will be raised
6.3.1.5
Monitoring alarm: ECM rating change
User can enable a monitoring alarm to detect changes in ECM rating level in the
Status
→
Monitoring
menu.
If the ECM rating level is below the descrambler rating level, the alarm will provide the value of the ECM
rating level. If the ECM rating level is above the descrambler rating level, the alarm will only notify that
the rating has gone above the descrambler rating level.
6.3.1.6
ECM Operator ID Filtering
Operator ID filtering is available for
Verimatrix bulk descrambler.
The edit menu for the
Verimatrix descrambler
have an Operator ID input.
•
Define Operator ID in the GUI:
•
Value: 0-255, 0 means any Operator ID.