Page 36 of 60
17. Initial Value and Adjustable Range of Soldering Condition
Condition
Initial setting
Adjustable range
Point soldering
1st
Amount
7.0mm
0-99.9mm
1st
Feed Speed
15.0mm/s
1-50.0mm/s
1st
Rev. Amount
3.0mm
0-99.9mm
1st
Rev. Speed
50.0mm/s
1-50.0mm/s
Pre-Heat Time
0.5sec
0-9.9sec
2nd
Amount
7.0mm
0-99.9mm
2nd
Feed Speed
10.0mm/s
1-50.0mm/s
2nd
Rev. Amount
3.0mm
0-99.9mm
2nd
Rev. Speed
50.0mm/s
1-50.0mm/s
Heating Time
1.0sec
0-9.9sec
3rd
Amount
0.0mm
0-99.9mm
3rd
Feed Speed
10.0mm/s
1-50.0mm/s
3rd
Rev. Amount
0.0mm
0-99.9mm
3rd
Rev. Speed
50.0mm/s
1-50.0mm/s
Condition
Initial setting
Adjustable range
Slide soldering
1st
Amount
7.0mm
0-99.9mm
1st
Feed Speed
15.0mm/s
1-50.0mm/s
1st
Rev. Amount
3.0mm
0-99.9mm
1st
Rev. Speed
50.0mm/s
1-50.0mm/s
Pre-Heat Time
0.5sec
0-9.9sec
2nd
Amount1
10.0mm
0-99.9mm
2nd
Feed Speed1
15.0mm/s
1-50.0mm/s
2nd
Amount2
0.0mm
0-99.9mm
2nd
Feed Speed2
15.0mm/s
1-50.0mm/s
2nd
Amount3
0.0mm
0-99.9mm
2nd
Feed Speed3
15.0mm/s
1-50.0mm/s
2nd
Amount4
0.0mm
0-99.9mm
2nd
Feed Speed4
15.0mm/s
1-50.0mm/s
Start pool time
0.0sec
0-9.9sec
2nd
Rev. Amount
3.0mm
0-99.9mm
2nd
Rev. Speed
50.0mm/s
1-50.0mm/s
Heating Time
0.0sec
0-9.9sec
Condition
Initial setting
Adjustable range
Easy Slide soldering
1st
Amount
7.0mm
0-99.9mm
1st
Feed Speed
15.0mm/s
1-50.0mm/s
1st
Rev. Amount
3.0mm
0-99.9mm
1st
Rev. Speed
50.0mm/s
1-50.0mm/s
Pre-Heat Time
0.5sec
0-9.9sec
2nd
Feed Speed
15.0mm/s
1-50.0mm/s
Start pool time
0.0sec
0-9.9sec
End pool time
0.0sec
0-9.9sec
2nd
Rev. Amount
3.0mm
0-99.9mm
2nd
Rev. Speed
50.0mm/s
1-50.0mm/s
Heating Time
0.0sec
0-9.9sec
Содержание J-CAT200 COMET
Страница 5: ...Page 5 of 60 3 Dimensions J CAT200 COMET...
Страница 6: ...Page 6 of 60 J CAT300 COMET...
Страница 7: ...Page 7 of 60 J CAT400 COMET...
Страница 8: ...Page 8 of 60 J CAT500 COMET...