ANGELUS SANITARY CAN MACHINE COMPANY
SERVICE NOTICE
9/9/99-18033004
3 of 14
Rev. 1 - 9/9/99
FILTRATION SYSTEM INFORMATION continued;
THE FOLLOWING OIL CAPACITIES ARE APPROXIMATIONS AND ARE PROVIDED FOR GENERAL
REFERENCE INFORMATION ONLY.
WATER FILTER
6
US QUARTS
PARTICULATE FILTER
6
US QUARTS
SEAMER UPPER TURRET HOUSING
6
US QUARTS
SEAMER LOWER TURRET HOUSING
8
US QUARTS
SEAMER BASE
21
US QUARTS
PIPING —
DEPENDS ON LENGTH AND SIZE
TRABON OIL SYSTEM GENERAL INFORMATION
TRABON SYSTEM INFORMATION.
THE TRABON OIL RESERVOIR CAPACITY IS APPROXI-
MATELY 345 CU. IN. AND THE PUMP OUTPUT CAPACITY
IS APPROXIMATELY 1.4 CU. IN. / MIN.. THEREFORE THE
TOTAL PUMP OUTPUT RUN TIME IS APPROXIMATELY
246
MIN. OR 4.1 HOURS FROM FULL TO EMPTY.
AS A MEANS OF OIL LEVEL LIMIT CONTROL AND INDICA-
TION, A DUAL MAGNET REED FLOAT SWITCH IS IN
STALLED BY ANGELUS IN THE TRABON OIL RESERVOIR.
THE LOW OIL SWITCH IS SET TO ACTIVATE 3.5 INCHES
ABOVE THE EMPTY RESERVOIR MARK WHICH WILL
GIVE
A 2.62" OIL HEEL (74.15 CU.IN.) THIS CONVERTS
TO A 53
MIN. RUN INTERVAL BEFORE THE TRABON
RESERVOIR
IS COMPLETELY EMPTY.
THE HIGH OIL SWITCH IS SET TO ACTIVATE 7.5" AB0VE
THE LOW OIL LEVEL SWITCH WHICH TRANSLATES
TO
211.85 CU.IN. OF OIL OR 2.5 HOURS OF RUN TIME
BE-
TWEEN THE HIGH OIL LEVEL SWITCH BEING ACTUATED AND THE LOW OIL LEVEL
SWITCH BEING
ACTUATED.
BETWEEN THE HIGH OIL LEVEL SWITCH ACTUATION POINT AND THE RESERVOIR FULL LEVEL
IS I” OF HEAD SPACE OR 28.25 CU.IN. OF OIL CAPACITY.
SEAMER OIL LUBRICATION SYSTEM PILOT DEVICE OPERATION, NOMENCLATURE
AND INDICATION MEANING.
THE FOLLOWING ASSUMES A STANDARD OIL LUBRICATION SYSTEM AND ITEMS MARKED WITH
AN ASTERISK (*) ARE PLC I/O POINT DEVICES.
*TRABON HIGH OIL LEVEL SWITCH. - N.C.
MAGNETIC REED FLOAT SWITCH WHICH OPENS WHEN THE TRABON RESERVOIR OIL LEVEL
REACHES IT’S DESIGNED FULL VALUE.
WHEN THE HIGH OIL LEVEL SWITCH OPENS THE REFILL/BOOST SOLENOID IS DE-ENER-
GIZED WHICH STOPS TRABON RESERVOIR REFILL.