Angelus Model 180S Seamer Instructions
5 OF 9
9/22/99 - 18033005
5. CELL DESCRIPTIONS AND OPERATION CONTINUED;
A. PAGE 0. MAIN SEAMER CONTROL.
A 7. INCH/RUN OPERATION
WHEN THE MEMBRANE KEY IS PRESSED AND THE CURSOR IS AROUND THE INCH RUN
SELECT CELL, THE CONTROL LABEL ASSOCIATED WITH THIS SELECTOR IS DISPLAYED AS
“ INCH SELECT”, BY PRESSING THE HARD PUSH BUTTON BY THIS LABEL, WITHIN THE
CELL THE FOLLOWING TEXT WILL SHOW AT WHICH LOCATION THE SEAMER CAN BE INCHED.
A 7.1
RUN SELECTED
A 7.2
INCH SELECTED AT OPERATOR STATION
A 7.3
INCH SELECTED AT REMOTE PENDANT
A 8. INCH
WHEN THE MEMBRANE KEY IS PRESSED AND THE CURSOR IS AROUND THE INCH CELL, THE
CONTROL LABEL ASSOCIATED WITH THIS SELECTOR IS DISPLAYED AS “PUSH TO INCIf’. BY
PRESSING THE HARD PUSH BUTTON, THE SEAMIER WILL ROTATE IN THE DIRECTION, AS
INDICATED BY THE TEXT WITHIN THE CELL;
A 8.1 INCH FORWARD
A 8.2 INCH REVERSE
A 9. CONTROL RESET
WHEN THE MEMBRANE KEY IS PRESSED AND THE CURSOR IS AROUND THE CONTROL
RESET CELL, THE CONTROL LABEL ASSOCIATED WITH THIS SELECTOR IS DISPLAYED AS
“CONTROL RESET”. BY PRESSING THE HARD PUSH BUTTON THE SEAMER WELL BE ENABLED
AND READY TO OPERATE. THE FOLLOWING TEXT WILL SHOW WHICH STATE THE RESET WILL
BE IN.
A 9.1
PUSH TO RESET
A 9.2
OK TO START (ENABLE)
A 10. GAS SYSTEM
WHEN THE MEMBRANE KEY IS PRESSED AND THE CURSOR IS AROUND THE GAS SYSTEM
CELL, THE CONTROL LABEL ASSOCIATED WITH THIS SELECTOR IS DISPLAYED AS “PUSH TO
PURGE”. BY PRESSING THE HARD PUSH BUTTON THE UNDER-COVER GASSING SYSTEM
WILL START. WITHIN THE CELL, THE FOLLOWING TEXT WILL DESCRIBE THE STATE WHICH THE
UNDERCOVER GASSING SYSTEM WILL BE IN.
A 10.1 NORMAL
A 10.2 PURGE REQUIRED
A 10.3 LOW GAS PRESSURE
A 10.4 HIGH GAS PRESSURE
A 11. RUN INTERLOCKS
WHEN THE MEMBRANE KEY IS PRESSED AND THE CURSOR IS AROUND THE RUN INTER
LOCKS CELL, WITHIN THE CELL WELL BE DISPLAYED THE STATUS OF THIS INDICATOR. THE
FOLLOWING TEXT WILL SHOW WHICH STATE THE INTERLOCKS ARE IN;
A 11.1 NORMAL
A 11.2 OPEN INTERLOCKS