ANGELUS SANITARY CAN MACHINE COMPANY
SERVICE NOTICE
3 of 3
6/16/95-18033003
NOTE:
We suggest aligning to the Brake Housing
machined surface because it provides a
more accurate alignment. There are two
readings to be taken. The first reading
will align the Motor Shaft vertically and
side to side (perimeter). The second reading
is the "Face Reading" which will align
the Shaft angularly. Both readings can
be performed using two dial indicators
mounted on the strap clamp at the same time.
C.
Secure all Sub-Base flange screws and
Support Pad Nuts.
Dial set for aligning the Face Reading.
D.
Place the dial indicator needle on the
front machined face of the Brake Housing.
Move the Motor on the Sub-Base angularly
until alignment is within .005 of an inch
all around the face surface. Secure Motor
mount fasteners.
E.
Re-check the Face Reading and
Perimeter Reading once all fasteners
have been secured.
F.
Install the drive coupling and all Guards.
Motor installed with Coupling Guard.