- 14 -
C1
39
60
360
0_
1.f
m
IT
AUS
DE
FR
ES
4 - Change the oven burner nozzle (see page 19)
5 - Change the oven burner pilot light nozzle (see
6 - If necessary, change the oven burner bushing
(see page20).
7 - Adjust the minimum setting on the plate and oven
gas control valve (see page 16/17 ).
8 - If necessary, replace the primary air bushing of
the plate burner (see page 19).
9 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.
If converting from Natural gas to Universal
LPG make sure the Natural Gas Regulator
is removed.
Important
Before it is put into service, the system
must be tested to check the operating con-
ditions of every single component and
identify any malfunctions. In this stage, it is
important to check that all health and safety
requirements have been complied with in
full.
To test the system, make the following checks:
1 - turn on the gas supply tap and check that the con-
nections are right;
2 - check that the mains gas is the same as that
used for commissioning of the appliance, and
carry out the conversion procedure if neces-
sary (see page 13);
3 - check that the plate and oven burners are lighting
correctly and their combustion;
4 - check the gas pressure and flow-rate at minimum
and maximum settings and adjust if necessary
(see page 16/17);
5 - check that the safety thermocouple is working
correctly;
6 - check that there are no gas leaks;
7 - check that the nameplates specify the correct gas
for the country of use.
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into opera-
tion in conditions of safety, in accordance with legal
requirements.
TESTING OF THE APPLIANCE
convers.gas aus.tif