C1
39
60
360
0_
1.f
m
- 13 -
IT
AUS
DE
FR
ES
To make the connection, connect the mains line to the
appliance's connection pipe, fitting a shut-off tap (
A
),
to allow the gas supply to be cut off when necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible
position and its status (on or off) must be
obvious at a glance.
This appliance shall be installed only by au-
thorised personnel and in accordance with
the manufacturer’s installation instruc-
tions, local gas fitting regulations, munici-
pal building codes, water supply
regulations, electrical wiring regulations,
As 5601/AG 601-Gas installations and any
other statutory regulations.
Always install a quick-closing ON-OFF valve (A) (not
supplied).
For Natural gas equipment, fit the gas regulator (B)
supplied with the appliance to gas connection.
Important
For natural gas equipment this appliance
must be fitted with a Bromic Oara 98 gas
regulator (AGA Approval N° 5862) supplied
with the appliance.
Do not use any other gas regulator. Ensure
regulator is fitted with respect to the gas
flow marked on the housing of the regula-
tor.
The constructor has tested the appliance with its own
mains gas, identified by the sticker applied to the
nameplate.
If the type of gas to be connected is different from that
used for testing, proceed as follows.
1 - Turn off the gas supply tap (
A
).
2 - Change the plate burner nozzle (see page 18).
3 - Change the plate burner pilot light nozzle (see
page 19).
GAS CONNECTION
CONVERSION OF THE GAS SUPPLY
IDM-3960200240.tif
A
IDM-39602002300.tif
A
1 rubin copia.tif
A