I
-
CT
39
60
36
00
_2
a.fm
(1) -Test point pressure
(2) - Nominal gas consumption
(2.1) - Main burner injector size
(3) - Turndown gas consumption
(3.1) - Bypass injector size
(3.2) -Bypass test point pressure
(4) - Pilot injector size
(1) -Test point pressure
(2) - Nominal gas consumption
(2.1) - Main burner injector size
(3) - Turndown gas consumption
(3.1) - Bypass injector size
(4) - Pilot injector size
(5) - Bushing areation opening
N.G.C. (2)
T.G.C. (3)
Pilot
Flame
GAS
TPP (1) Supply pressure
G.C.
Ø (2.1)
G.C.
Ø (3.1)
p(3.2)
Ø (4)
NGN
0.8 kPa
1.13 kPa
40 MJ/h
3.20 mm
16 MJ/h
1.10 mm adj-pressure
0.10kPa
0.40 mm
ULPG
2.75 kPa
2.75 kPa
40 MJ/h
1.75 mm
16 MJ/h
1.10 mm
NO adj
All screw
0.25 mm
- OVEN BURNER -
N.G.C. (2)
T.G.C. (3)
Pilot Flame Iron Ring
GAS
TPP (1)
Supply
pressure
G.C.
Ø (2.1)
G.C.
Ø (3.1)
Ø (4)
Ø (5)
NGN
0.8 kPa
1.13 kPa
18 MJ/h
2.00 mm
4.4 MJ/h
1.00 mm
0.40 mm
9xØ6.25mm
Fully open
ULPG
2.75 kPa
2.75 kPa
18 MJ/h
1.10 mm
4.4 MJ/h
0.50 mm
0.25 mm
9xØ6.25mm
Fully open
- PLATE BURNER -