The appliance has been tested before being put into
service. The information provided below is intended
to assist in the identification and correction of any
anomalies and malfunctions which might occur dur-
ing use. The user can solve some of these problems
himself, but for others specific technical knowledge or
skill is required, and so they must only be carried out
by qualified staff with recognised experience ac-
quired in the specific sector of operation.
FAULT
6
TROUBLESHOOTING
Fault
Causes
Remedies
Smell of gas.
Occasional leak because flame
has gone out.
Turn off the gas supply tap and
ventilate the room.
The pilot light does not ignite.
The spark ignition devices are not
working.
Check that the ignition devices are
in good working order. Light by
hand with a naked light.
Contact the
after-sales service.
Air in pipelines due to long period
out of use.
Make more attempts to
light the flame.
The pilot light goes out.
The thermocouple has not warmed
up enough.
Make more attempts to
light the flame.
The pilot light ignites but the burner
remains off.
Check the condition of the
thermostat and activate any
ignition enabling device.
The flame is yellow.
Burner dirty, heat exchange pipes
clogged, condensation drips.
Contact the after-sales service.
Burner control knob is stiff.
Gas control valve malfunction.
Contact the after-sales service.