- 16 -
C1
39
60
36
00
_1
.fm
IT
AUS
DE
FR
ES
Important
Before making any type of adjustment, acti-
vate all the safety devices provided and de-
cide whether staff at work and those in the
vicinity should be informed.
In particular, turn off the gas supply tap and
prevent access to all devices which might
cause unexpected health and safety haz-
ards if turned on.
Important
This adjustment is only required if the type
of gas to be connected is different from that
used for testing after the conversion proce-
dure has been carried out (see page
13).
Before making this adjustment, check that
the gas supply pressure is the same as the
rated pressure for the type of gas in use
(see table at back of manual).
Natural gas
In this case the gas pres-
sure upstream of the nozzle has
to be adjusted; proceed as fol-
lows.
1- Turn off the gas supply tap.
2 - Pull off the knob (
A
).
3 - Undo the screws (
B
) and
remove the control panel
(
C
).
4 - Turn the screw to open the
pressure connection (
D
).
5 - Connect the pressure
gauge (
E
) to the pressure
test point (
D
).
6 - Turn the gas supply tap back on.
7 - Light the burner and turn the knob to the minimum
flame setting.
8 - Fit the minimum flow injector (
F
), screwing it fully
down
9 - Slowly unscrew the injector (
F
) until the pressure
reading complies with the values in the table (see
back of manual).
10 - Check the stability of the flame.
N.B.: after adjusting, seal the screw with paint.
11 - Turn off the burner, disconnect the pressure
gauge and restore the initial conditions after com-
pleting the operation.
Liquid gas
To carry out this operation, proceed as follows.
1- Turn off the gas supply tap.
2 - Pull off the knob (
A
).
3 - Undo the screws (
B
) e remove the control panel
(
C
).
4 - Screw the minimum flow injector fully down (
F
).
N.B.: after adjusting, seal the screw with paint.
5 - Restore the initial conditions after completing the
operation.
ADJUSTMENTS
8
RECOMMENDATIONS FOR ADJUSTMENTS
ADJUSTING PLATE GAS CONTROL VALVE MINIMUM SETTING
IDM-39603617900.tif
C
D
A
B
F
E