background image

 

 

CPRC SIP DECIMAL POS 
 

 

 
 

ÿü

 to change, 

õö

 to choose, 

ÿþ

 to save 

 
Definition:  This parameter selects number of decimal places to be used 

for CPRC simulated input. 

 

ÿø

 TO ADVANCE TO NEXT SELECTION 

 
 
 

 

 CPRC SIP DISPLAY TAG 
 

[ USER ENTERED TEXT ] 

 

 

 

 

 

 

ñ

 NOTE:  Refer to General Instrument Operation - Modifying Text 

for information on this operation. 

 
Definition:  This text parameter defines the CPRC tag that is shown on 

the user display. 

 

ÿø

 TO ADVANCE TO NEXT SELECTION 

 

 

CPRC SIP RANGE LOW 
 

 

 
 

ÿü

 to change, 

õö

 to choose, 

ÿþ

 to save 

 
Definition:  This parameter selects the low range to be used for CPRC 

simulated input. 

 

ÿø

 TO ADVANCE TO NEXT SELECTION 

 

 

CPRC SIP RANGE HIGH 
 

 

 
 

Revision 3.0 

Section 7 

28 

 

Содержание AV-9900

Страница 1: ...Anderson Instrument Co Inc 156 Auriesville Rd Fultonville NY 12072 Phone 800 833 0081 www anderson negele com Instruction Manual Rev 3 0 Doc 1029 AV 9900 Microprocesor Based HTST Recorder Controller...

Страница 2: ......

Страница 3: ...r 6 Controller Setup Menu programming Chapter 7 Configuration Menu programming Chapter 8 Test routines Chapter 9 Calibration routines Chapter 10 Model and Revision info Chapter 11 Chart Operation Appe...

Страница 4: ...icting access to the Run Program shunt jumper the chart plate seal prevents modifications to circuit boards and input output wiring connections Flow Diversion Valve position is indicated by red and gr...

Страница 5: ...ry the resulting output signal based on rising above or falling below the desired Hot Water set point If various products are being processed up to five Hot Water Controllers are available one for eac...

Страница 6: ......

Страница 7: ...are enclosed in a cardboard box within the container holding the unit Be sure to secure these items before discarding shipping material Select a location for the instrument which is accessible clean w...

Страница 8: ...eliminate interference be sure to isolate signal cables from power cables when entering recorder CAUTION To prevent moisture entry or damage to components DO NOT cut case penetrations in sides or top...

Страница 9: ...er Supply F1 F2 110 VAC F1 F2 3 amp 220 VAC F1 F2 1 5 amp 7 6 5 4 3 2 L2 TB1 HTST Termination Board Fuses 110 VAC 220 VAC As Per Order Review Instrument Data Tag Prior To Making Field Connections CAUT...

Страница 10: ...vary based on the configuration ordered CAUTION Disconnect power to the instrument to prevent electrical shock or component damage 2 5 1 Legal Controls Wiring Wiring to the legal controls FDV Differen...

Страница 11: ...less specified at time of order all programming and jumper selections have been pre set at the factory Note The following chart outlines board locations for Input s only Board Location LEFT Input Chan...

Страница 12: ...ed cable If wires are removed for installation purposes they must be re wired properly CAUTION Anderson does not recommend splicing of signal cable The possibility will exist for corrosion leading to...

Страница 13: ...hould first determine which input you will be working with Cold Product or Hot Water it s type RTD or mA and finally which terminal it wires to The following diagram illustrates the wiring and configu...

Страница 14: ...ered or Un powered This can be accomplished by placing a meter DC Volts position across the two sensor leads If a voltage is observed the signal is said to be Powered Wiring can go directly to the mA...

Страница 15: ...mitter Power Supply Wiring 2 5 8 mA Retransmission Output Board Wiring Refer to the circuit board locations diagram for assistance in locating the mA retransmission board Retransmission signals are ut...

Страница 16: ...and NO terminals for failsafe operation Relay 2 SFLR Alarm 2 High Flow alarm Wire to COM and NO terminals for failsafe operation Relay contacts interface with Legal Flow Control unit found in system...

Страница 17: ...This section will detail specifics relating to overall operation of the unit 3 1 Installation of pen cartridge assembly Remove the pen cartridge assembly from its shipping container With mounting tab...

Страница 18: ...m parameters can be gained A description of each of the keys is as follows Up Arrow Key Used to move through menus or increase a value Down Arrow Key Used to move through menus or decrease a value Lef...

Страница 19: ...ode for completion of the Appendix I Pasteurized Milk Ordinance testing While in sequence mode various parameters scroll over the screen at a timed interval 3 4 1 Display Continuous Mode 1 Operation m...

Страница 20: ...the temperature input to the STLR portion of the system A continuous check is made between the two elements Match to 5 O F shift No LED s lit operation allowed 5 O F to 1 O F shift 1 LED lit Forward...

Страница 21: ...th the new value being displayed and entered into memory 3 5 2 Changing Text There are two ways to modify text The first Character Modify is accessed by the initial pressing of the key and the second...

Страница 22: ...key exits Character Selection and return the unit to Character Modify where selection of another character may be made or again exits Modify While in Character Selection key after modifying a characte...

Страница 23: ...tpoint changes etc Changes may be made to display functions as well as selection of the currently active diversion setpoint While in PROGRAM mode full access to all system parameters is allowed NOTE M...

Страница 24: ...Revision 3 0 Section 3 8...

Страница 25: ...rally used when we have completed a processing run and wish to remove the chart from the AV 9900 The procedure is as follows 1 key to initiate Stop Chart routine 2 Display will show STOP CHART NO YES...

Страница 26: ...uence for up to 5 minutes When exiting the Hold sequence the chart printing will be accelerated until the point where real time has again been reached NOTE Chart HOLD may only be initiated while in RU...

Страница 27: ...Chart will begin printing at an accelerated speed until all data and events have been transfered from memory to the chart and real time has again been reached 4 2 How Do I Change an STLR Diversion Set...

Страница 28: ...the controllers may be placed into Manual mode While in Manual a percentage of output 0 100 may be directly altered by the user This change will immediately influence the resulting controller output...

Страница 29: ...for PID mode of operation modulating 4 20 mA output or On Off mode of operation Relay NOTE A menu option exists for selecting whether or not setpoint changes may be made from the RUN mode If set to NO...

Страница 30: ...r Setup Menu while in the Program mode If set to YES changes may be made as shown in the upcoming section To toggle this function refer to the appropriate CP HW or SF Controller Setup Menu in section...

Страница 31: ...the Factory Prior to making modifications it is recommended that you record current settings 5 1 Function Setup Menu STLR The following section STLR Safety Thermal Limit Recorder will illustrate the...

Страница 32: ...hange or to choose to save Definition If STLR Input is being displayed this parameter selects whether both input 1 Primary and input 2 Secondary are displayed or if only input 1 Primary is displayed T...

Страница 33: ...and May or may not indicate forward flow condition dependent on presence of SFLR function TO ADVANCE TO NEXT SELECTION STLR SP DISPLAY OPT NOT DISPLAYED IN CONTINUOUS MODE IN SEQUENTIAL MODE IN BOTH M...

Страница 34: ...il the following is visible SELECT FUNCTION SETUP With FUNCTION shown in the lower display line key The following will now be visible on the user display SELECT FUNCTION STLR XXXX XXXX NOTE XXXX will...

Страница 35: ...CK BLUE GREEN NOT RECORDED to change or to choose to save Definition This parameter determines if the temperature from the Hot Product Probe input is printed to the chart and if so in which color The...

Страница 36: ...E O C shown if unit set for Celsius to change to choose to save Definition This parameter allows a correction factor to be added to the STLR Input Values It is used to correct discrepancies between th...

Страница 37: ...so in which color The factory default is GREEN TO ADVANCE TO NEXT SELECTION STLR SP DISPLAY OPT NOT DISPLAYED IN CONTINUOUS MODE IN SEQUENTIAL MODE IN BOTH MODES to change to choose to save Definitio...

Страница 38: ...or instructions on identifying RUN and PROGRAM mode of operation From the Normal Display key until the following is visible SELECT FUNCTION SETUP With FUNCTION shown in the lower display line key The...

Страница 39: ...MODE IN BOTH MODES to change to choose to save Definition This parameter when active will display the output of the CPRC PID Controller A Controller MUST be active The units will be in of output TO A...

Страница 40: ...the Normal Display key until the following is visible SELECT FUNCTION SETUP With FUNCTION shown in the lower display line key The following will now be visible on the user display SELECT FUNCTION STLR...

Страница 41: ...ure current output selected is not used by another function to change to choose to save Definition This parameter allows the CPRC Input signal to be sent out as a 4 20 mA retransmission signal TO ADVA...

Страница 42: ...de to change to choose to save Definition This parameter allows a correction factor to be added to the Cold Product input value It is used to correct discrepancies between the actual cold product valu...

Страница 43: ...RC OUT RECORDING RED BLACK BLUE GREEN NOT RECORDED to change or to choose to save Definition This parameter when active will record the resulting output of the CPRC PID Controller Only applies if PID...

Страница 44: ...change to choose to save Definition This parameter if active allows the current Setpoint of the PID controller associated with the Cold Product to be displayed TO ADVANCE TO NEXT SELECTION CPRC ALARM...

Страница 45: ...ave Definition This parameter allows the user to select an optional alarm for the Cold Product process This alarm may be tied to an event flag LED or relay TO ADVANCE TO NEXT SELECTION CPRC ALARM2 SET...

Страница 46: ...ent on activation by another parameter Access is gained as follows Note Refer to General Instrument Operations section for instructions on identifying RUN and PROGRAM mode of operation From the Normal...

Страница 47: ...to choose to save Definition This parameter when active displays the output of the controller associated with the Hot Water function TO ADVANCE TO NEXT SELECTION HWC SP DISPLAY OPT NOT DISPLAYED IN CO...

Страница 48: ...he Normal Display key until the following is visible SELECT FUNCTION SETUP With FUNCTION shown in the lower display line key The following will now be visible on the user display SELECT FUNCTION STLR...

Страница 49: ...sure current output selected is not used by another function to change to choose to save Definition This parameter allows the HWC Input signal to be sent out as a 4 20 mA retransmission signal TO ADV...

Страница 50: ...This parameter allows the user to choose the type of control action applied to the HWC control output TO ADVANCE TO NEXT SELECTION HWC CURRENT OUTPUT 1 THROUGH 4 NOTE This parameter only active if PI...

Страница 51: ...NTINUOUS MODE IN SEQUENTIAL MODE IN BOTH MODES to change to choose to save Definition This parameter when active will display the resulting output of the HWC PID Controller if controller is active TO...

Страница 52: ...YPE NONE OFF LOW SIGNAL VALUE HIGH RATE VALUE to change to choose to save Definition This parameter allows the user to select an optional alarm for the Hot Water Loop This alarm may be tied to an even...

Страница 53: ...larm may be tied to an event flag LED or relay TO ADVANCE TO NEXT SELECTION HWC ALARM2 SETPOINT X O F NOTE Will display in O C if unit set for Celcius to change to choose to save Definition This param...

Страница 54: ...pendent on activation by another parameter Access is gained as follows Note Refer to General Instrument Operations section for instructions on identifying RUN and PROGRAM mode of operation From the No...

Страница 55: ...hoose to save Definition This parameter when active displays the output of the controller associated with the SFLR function TO ADVANCE TO NEXT SELECTION SFLR SP DISPLAY OPT NOT DISPLAYED IN CONTINUOUS...

Страница 56: ...mode of operation From the Normal Display key until the following is visible SELECT FUNCTION SETUP With FUNCTION shown in the lower display line key The following will now be visible on the user disp...

Страница 57: ...ave Definition This parameter selects NORMAL run mode with a SIMULATED run mode option for demonstration purposes TO ADVANCE TO NEXT SELECTION SFLR INP TRANSMIT TO CURRENT OUTPUT X NOTE X Current outp...

Страница 58: ...YED to change to choose to save Definition This parameter when active will display the Flow Rate input value TO ADVANCE TO NEXT SELECTION SFLR INP CORRECTION X units NOTE Units as programmed will be d...

Страница 59: ...NCE TO NEXT SELECTION SFLR CURRENT OUTPUT 1 THROUGH 4 NOTE This parameter only active if PID chosen as control type to change to choose to save Definition This parameter will tie a PID control output...

Страница 60: ...NTINUOUS MODE IN SEQUENTIAL MODE IN BOTH MODES to change to choose to save Definition This parameter when active will display the resulting output of the SFLR PID Controller if controller is active TO...

Страница 61: ...ut This function is NOT utilized on typical Pasteurization loops SFLR ALARM1 TYPE NONE OFF LOW SIGNAL VALUE HIGH RATE VALUE to change to choose to save Definition MUST remain at High Rate Value select...

Страница 62: ...ition MUST remain at LOW SIGNAL VALUE selection for proper utilization as High Flow alarm Causes Alarm 2 relay to be failsafe active when above High Flow setpoint Above High Flow setpoint condition wi...

Страница 63: ...This completes SFLR program options to return to main display or to return to start of FUNCTION MENU Revision 3 0 Section 5 33...

Страница 64: ......

Страница 65: ...difications to program parameters on a unit that has been in operation RECORD ALL PARAMETERS before making changes 6 1 Controller Setup Menu STLR 6 1 1 STLR Shunt Position PROGRAM MODE While in the PR...

Страница 66: ...ER ENTERED TEXT NOTE Refer to General Instrument Operation Modifying Text for information on this operation Definition This text parameter defines the tag that is shown on the user display for the STL...

Страница 67: ...XT SELECTION STLR SPX VALUE Y UNITS X Diversion Setpoint 1 through 5 Y Setpoint Value Units O F or O C as chosen in setup to change to choose to save Definition This parameter is one of the 5 availabl...

Страница 68: ...OUGH 5 to change to choose to save Definition This value allows the selection of currently active STLR Diversion Setpoint while in the STLR Control er Program Menu l NOTE The new Diversion Setpoint do...

Страница 69: ...given if no Cold Product or Hot Water controllers active key until STLR is flashing then key to select Available parameters are STLR CURRENT SP 1 THROUGH 5 to change to choose to save Definition This...

Страница 70: ...RC Control related parameters Access is gained as follows From the Normal Display press the key until the following is visible SELECT CONTROLLER SETUP With FUNCTION shown in the lower display line key...

Страница 71: ...O NEXT SELECTION CPRC CONTROL TUNING YES NO to change or to choose to save Definition This parameter determines if CPRC Controller ON OFF tuning parameters are accessible while the unit is in RUN mode...

Страница 72: ...own for the CPRC ON OFF Setpoint as shown on the user display TO ADVANCE TO NEXT SELECTION CPRC NUMBER SETPOINTS 0 THROUGH 1 to change to choose to save Definition This parameter determines whether th...

Страница 73: ...TO ADVANCE TO NEXT SELECTION CPRC HYSTERESIS Y UNITS Y Proportional Band Value Units O F or O C as chosen in setup to change to choose to save Definition This parameter defines the CPRC ON OFF Hyster...

Страница 74: ...display line key The following will now be visible on the user display CONTROL FUNCTION STLR XXXX XXXX NOTE XXXX will be vary depending on which options the unit has key until CPRC is flashing key to...

Страница 75: ...oller Output may be forced to a percentage of signal This will ensure a safe condition during the error period Ex Air To Open valve 0 will ensure valve stays closed TO ADVANCE TO NEXT SELECTION CPRC O...

Страница 76: ...fines the tag that is shown on the user display for the CPRC PID Control Output TO ADVANCE TO NEXT SELECTION CPRC OUT DECIMAL POS 0 THROUGH 3 to change to choose to save Definition This parameter dete...

Страница 77: ...R ERR SFLR OUT SFLR ERR FLOW OUT FLOW ERR CPRC OUT CPRC ERR HWC OUT HWC ERR OP INP 1 OP INP 2 OP INP 3 OP INP 4 OP INP 5 OP INP 6 OP INP 7 OP INP 8 DA1 DA2 DA3 DA4 DA5 DA6 DA7 DA8 F1 F2 F3 F4 F5 RESET...

Страница 78: ...ose to save Definition This parameter determines if CPRC Controller PID Setpoint is accessible while the unit is in RUN mode TO ADVANCE TO NEXT SELECTION CPRC SP DISPLAY TAG USER ENTERED TEXT NOTE Ref...

Страница 79: ...o save Definition This parameter determines whether the PID controll is active or not A 0 de selects the controller while a 1 will bring up the remainder of options NOTE Toggling this value will immed...

Страница 80: ...r defines the CPRC PID controller setpoint value TO ADVANCE TO NEXT SELECTION CPRC PROP BAND Y UNITS Y Proportional Band Value Units O F or O C as chosen in setup to change to choose to save Definitio...

Страница 81: ...NCE TO NEXT SELECTION CPRC AUTO RESET Y REPEATS MIN Y Auto Reset Value to change to choose to save Definition This parameter provides an Automatic Reset value used by the PID algorithm TO ADVANCE TO N...

Страница 82: ...This completes CPRC Controller program options to return to main display or to return to start of CONTROLLER MENU Revision 3 0 Section 6 18...

Страница 83: ...following is visible SELECT CONTROLLER SETUP With FUNCTION shown in the lower display line key The following will now be visible on the user display CONTROL FUNCTION STLR XXXX XXXX NOTE XXXX will be v...

Страница 84: ...TO NEXT SELECTION HWC CONTROL TUNING YES NO to change or to choose to save Definition This parameter determines if HWC controller ON OFF tuning parameters are accessible while the unit is in RUN mode...

Страница 85: ...ON OFF setpoint as shown on the user display TO ADVANCE TO NEXT SELECTION HWC NUMBER SETPOINTS 0 THROUGH 1 to change to choose to save Definition This parameter determines whether the ON OFF controll...

Страница 86: ...XT SELECTION HWC SP1 HYSTERESIS Y UNITS Y Proportional Band Value Units O F or O C as chosen in setup to change to choose to save Definition This parameter defines the HWC ON OFF hysteresis deadband v...

Страница 87: ...er display line key The following will now be visible on the user display CONTROL FUNCTION STLR XXXX XXXX NOTE XXXX will be vary depending on which options the unit has key until HWC is flashing key t...

Страница 88: ...oller output may be forced to a percentage of signal This will ensure a safe condition during the error period Ex Air To Open valve 0 will ensure valve stays closed TO ADVANCE TO NEXT SELECTION HWC OU...

Страница 89: ...efines the tag that is shown on the user display for the HWC PID control output TO ADVANCE TO NEXT SELECTION HWC OUT DECIMAL POS 0 THROUGH 3 to change to choose to save Definition This parameter deter...

Страница 90: ...R ERR SFLR OUT SFLR ERR FLOW OUT FLOW ERR CPRC OUT CPRC ERR HWC OUT HWC ERR OP INP 1 OP INP 2 OP INP 3 OP INP 4 OP INP 5 OP INP 6 OP INP 7 OP INP 8 DA1 DA2 DA3 DA4 DA5 DA6 DA7 DA8 F1 F2 F3 F4 F5 RESET...

Страница 91: ...ose to save Definition This parameter determines if HWC controller PID setpoint is accessible while the unit is in RUN mode TO ADVANCE TO NEXT SELECTION HWC SP DISPLAY TAG USER ENTERED TEXT NOTE Refer...

Страница 92: ...save Definition This parameter determines whether the PID controll is active or not A 0 de selects the controller while a 1 will bring up the remainder of options NOTE Toggling this value will immedi...

Страница 93: ...al Band Value Units O F or O C as chosen in setup to change to choose to save Definition This parameter defines the HWC PID controller Proportional Band value TO ADVANCE TO NEXT SELECTION HWC INTEG BA...

Страница 94: ...e PID algorithm TO ADVANCE TO NEXT SELECTION HWC RATE Y MINUTES Y Rate Value to change to choose to save Definition This parameter provides a Rate value used by the PID algorithm TO ADVANCE TO NEXT SE...

Страница 95: ...Control related parameters Access is gained as follows From the Normal Display press the key until the following is visible SELECT CONTROLLER SETUP With FUNCTION shown in the lower display line key Th...

Страница 96: ...O NEXT SELECTION SFLR CONTROL TUNING YES NO to change or to choose to save Definition This parameter determines if SFLR Controller ON OFF tuning parameters are accessible while the unit is in RUN mode...

Страница 97: ...wn for the SFLR ON OFF Setpoint as shown on the user display TO ADVANCE TO NEXT SELECTION SFLR NUMBER SETPOINTS 0 THROUGH 1 to change to choose to save Definition This parameter determines whether the...

Страница 98: ...ADVANCE TO NEXT SELECTION SFLR HYSTERESIS Y UNITS Y Proportional Band Value Units O F or O C as chosen in setup to change to choose to save Definition This parameter defines the SFLR ON OFF Hysteresi...

Страница 99: ...own in the lower display line key The following will now be visible on the user display CONTROL FUNCTION STLR XXXX XXXX NOTE XXXX will be vary depending on which options the unit has key until SFLR is...

Страница 100: ...oller Output may be forced to a percentage of signal This will ensure a safe condition during the error period Ex Air To Open valve 0 will ensure valve stays closed TO ADVANCE TO NEXT SELECTION SFLR O...

Страница 101: ...fines the tag that is shown on the user display for the SFLR PID Control Output TO ADVANCE TO NEXT SELECTION SFLR OUT DECIMAL POS 0 THROUGH 3 to change to choose to save Definition This parameter dete...

Страница 102: ...SFLR ERR FLOW OUT FLOW ERR CPRC OUT CPRC ERR HWC OUT HWC ERR OP INP 1 OP INP 2 OP INP 3 OP INP 4 OP INP 5 OP INP 6 OP INP 7 OP INP 8 DA1 DA2 DA3 DA4 DA5 DA6 DA7 DA8 F1 F2 F3 F4 F5 RESET MOD ENTER to c...

Страница 103: ...ose to save Definition This parameter determines if SFLR Controller PID Setpoint is accessible while the unit is in RUN mode TO ADVANCE TO NEXT SELECTION SFLR SP DISPLAY TAG USER ENTERED TEXT NOTE Ref...

Страница 104: ...o save Definition This parameter determines whether the PID controll is active or not A 0 de selects the controller while a 1 will bring up the remainder of options NOTE Toggling this value will immed...

Страница 105: ...al Band Value Units As chosen in setup to change to choose to save Definition This parameter defines the SFLR PID controller Proportional Band value TO ADVANCE TO NEXT SELECTION SFLR INTEG BAND Y UNIT...

Страница 106: ...PID algorithm TO ADVANCE TO NEXT SELECTION SFLR RATE Y MINUTES Y Rate Value to change to choose to save Definition This parameter provides a Rate value used by the PID algorithm TO ADVANCE TO NEXT SE...

Страница 107: ...te Refer to General Instrument Operations section for instructions on identifying RUN and PROGRAM mode of operation From the Normal Display key until the following is visible SELECT CONFIGURATION With...

Страница 108: ...er allows setting the current date TO ADVANCE TO NEXT SELECTION CURRENT TIME AM PM XX XX XX to change to choose Hour to save to change to choose Minutes to save to change to choose AM PM to save Defin...

Страница 109: ...eration From the Normal Display key until the following is visible SELECT CONFIGURATION With CONFIGURATION shown in the lower display line key The following will now be visible on the user display CON...

Страница 110: ...g is a user entered string which may be viewed on the display TO ADVANCE TO NEXT SELECTION TEMPERATURE UNITS O X to change to choose to save Definition This parameter selects units of operation O F or...

Страница 111: ...o save to change to choose Day to save to change to choose Year to save Definition This parameter allows setting the current date TO ADVANCE TO NEXT SELECTION CURRENT TIME AM PM XX XX XX to change to...

Страница 112: ...to save Definition This parameter selects communications bit rate NOTE Not available for use in field applications TO ADVANCE TO NEXT SELECTION COMMS PARITY ODD EVEN NONE to change to choose to save...

Страница 113: ...ructions on identifying RUN and PROGRAM mode of operation From the Normal Display key until the following is visible SELECT CONFIGURATION With CONFIGURATION shown in the lower display line key until t...

Страница 114: ...ag that is shown on the user display TO ADVANCE TO NEXT SELECTION STLR INP DECIMAL POS X to change to choose to save Definition This parameter selects active decimal places for the STLR user display T...

Страница 115: ...tenance Two Point Hot Product Probe Calibration to change value to choose to save to change correction to choose to save Definition This is a correction parameter used for the low end of the primary e...

Страница 116: ...choose to save Definition This is a correction parameter used for the low end of the secondary element in the Hot Product probe TO ADVANCE TO NEXT SELECTION STLR INPUT 2 CORR 2 X AT X NOTE This parame...

Страница 117: ...o General Instrument Operation Modifying Text for information on this operation Definition This text parameter defines the SFLR Input Tag that is shown on the user display TO ADVANCE TO NEXT SELECTION...

Страница 118: ...EXT SELECTION SFLR INP LIMIT LOW X to change to choose to save Definition This parameter selects low limit for the SFLR input This setting is in units as determined in Function Setup Be sure setting e...

Страница 119: ...rrection parameter used for the low end of the SFLR input TO ADVANCE TO NEXT SELECTION SFLR INPUT 1 CORR 2 X AT X NOTE This parameter is documented in Instrument Maintenance SFLR Input Calibration to...

Страница 120: ...TYPE RTD Ma to change to choose to save Definition This parameter selects the CPRC input type TO ADVANCE TO NEXT SELECTION CPRC INP RTD TYPE PT 100 00385 DIN PT 100 00392 USA PT 100 00392 SAMA NI 100...

Страница 121: ...eter selects active decimal places for the CPRC user display TO ADVANCE TO NEXT SELECTION CPRC INP RANGE LOW X NOTE Not shown if input type RTD Definition This parameter selects low input range for th...

Страница 122: ...er selects high limit for the CPRC input This is a factory default setting TO ADVANCE TO NEXT SELECTION CPRC INPUT 1 CORR 1 X AT X NOTE This parameter is documented in Instrument Maintenance CPRC Inpu...

Страница 123: ...RC input TO ADVANCE TO NEXT SELECTION This completes the CPRC Input setup menus to return to the normal display or to continue to the next input selection INPUT FUNCTION HWC Start of menu options for...

Страница 124: ...Operation Modifying Text for information on this operation Definition This text parameter defines the HWC Input Tag that is shown on the user display TO ADVANCE TO NEXT SELECTION HWC INP DECIMAL POS...

Страница 125: ...ange for the HWC input Typical setting is 20 00 mA MUST match output of sensor TO ADVANCE TO NEXT SELECTION HWC INP LIMIT LOW X Definition This parameter selects low limit for the HWC input This is a...

Страница 126: ...NEXT SELECTION HWC INPUT 1 CORR 2 X AT X NOTE This parameter is documented in Instrument Maintenance HWC Input Calibration to change value to choose to save to change correction to choose to save Def...

Страница 127: ...rameters which affect the simulated inputs All parameters may not be accessible as many are dependent on activation by another parameter Access is gained as follows Note Refer to General Instrument Op...

Страница 128: ...lable parameters are STLR SIM SELECTION PRIMARY SECONDARY to change to choose to save Definition This parameter selects start of simulated input setup either Primary or Secondary simulation TO ADVANCE...

Страница 129: ...Operation Modifying Text for information on this operation Definition This text parameter defines the STLR PRIMARY SIP tag that is shown on the user display TO ADVANCE TO NEXT SELECTION STLR SIP RANG...

Страница 130: ...save Definition This parameter selects the period to be used for PRIMARY simulated input TO ADVANCE TO NEXT SELECTION STLR SIS TYPE OFF NO INPUT SINE WAVE SAWTOOTH SQUARE WAVE SPIKES to change to choo...

Страница 131: ...oose to save Definition This parameter selects the high range to be used for SECONDARY simulated input TO ADVANCE TO NEXT SELECTION STLR SIS PERIOD X to change to choose to save Definition This parame...

Страница 132: ...number of decimal places to be used for SFLR simulated input TO ADVANCE TO NEXT SELECTION SFLR SIP DISPLAY TAG USER ENTERED TEXT NOTE Refer to General Instrument Operation Modifying Text for informati...

Страница 133: ...or SFLR simulated input TO ADVANCE TO NEXT SELECTION SFLR SIP PERIOD X to change to choose to save Definition This parameter selects the period to be used for SFLR simulated input TO ADVANCE TO NEXT S...

Страница 134: ...OTE Refer to General Instrument Operation Modifying Text for information on this operation Definition This text parameter defines the CPRC tag that is shown on the user display TO ADVANCE TO NEXT SELE...

Страница 135: ...nge to choose to save Definition This parameter selects the period to be used for CPRC simulated input TO ADVANCE TO NEXT SELECTION HWC SIP TYPE OFF NO INPUT SINE WAVE SAWTOOTH SQUARE WAVE SPIKES to c...

Страница 136: ...to General Instrument Operation Modifying Text for information on this operation Definition This text parameter defines the HWC tag that is shown on the user display TO ADVANCE TO NEXT SELECTION HWC S...

Страница 137: ...s the high range to be used for HWC simulated input TO ADVANCE TO NEXT SELECTION HWC SIP PERIOD X to change to choose to save Definition This parameter selects the period to be used for HWC simulated...

Страница 138: ...r parameter The available current outputs are STLR INPUT mA retransmission of STLR Input Temperature SFLR INPUT mA retransmission of SFLR Input Signal SFLR OUTPUT mA output from SFLR PID Controller CP...

Страница 139: ...ed variable have been programmed the unit will automatically scroll to the next available function will return to the normal display or will continue to advance through the next parameter set Availabl...

Страница 140: ...STLR INP RANGE HIGH X to change to choose to save Definition This parameter selects the range high to be used by output signal Typically matches high end of STLR chart range TO ADVANCE TO NEXT SELECT...

Страница 141: ...save Definition This parameter selects the decimal place to be used if output signal displayed or recorded TO ADVANCE TO NEXT SELECTION SFLR INP RANGE LOW X to change to choose to save Definition This...

Страница 142: ...FLR INP ERROR VALUE X to change to choose to save Definition This parameter selects the resulting output signal upon an error condition TO ADVANCE TO NEXT SELECTION SFLR OUT CO TYPE 0 20 mA 4 20 mA to...

Страница 143: ...used by output signal Typically matches low end of SFLR chart range TO ADVANCE TO NEXT SELECTION SFLR INP RANGE HIGH X to change to choose to save Definition This parameter selects the range high to b...

Страница 144: ...L POS X to change to choose to save Definition This parameter selects the decimal place to be used if output signal displayed or recorded TO ADVANCE TO NEXT SELECTION CPRC INP RANGE LOW X to change to...

Страница 145: ...PRC INP ERROR VALUE X to change to choose to save Definition This parameter selects the resulting output signal upon an error condition TO ADVANCE TO NEXT SELECTION CPRC OUT CO TYPE 0 20 mA 4 20 mA to...

Страница 146: ...ve Definition This parameter selects the range low to be used by output signal Typically matches low end of CPRC chart range TO ADVANCE TO NEXT SELECTION CPRC INP RANGE HIGH X to change to choose to s...

Страница 147: ...4 20 mA to change to choose to save Definition This parameter selects the type of HWC Input Signal Retransmission TO ADVANCE TO NEXT SELECTION HWC INP DECIMAL POS X to change to choose to save Definit...

Страница 148: ...X to change to choose to save Definition This parameter selects the range high to be used by output signal Typically matches high end of HWC chart range TO ADVANCE TO NEXT SELECTION HWC INP ERROR VAL...

Страница 149: ...e to save Definition This parameter selects the decimal place to be used if output signal displayed or recorded TO ADVANCE TO NEXT SELECTION HWC OUT RANGE LOW X to change to choose to save Definition...

Страница 150: ...ed by output signal Typically matches high end of HWC chart range TO ADVANCE TO NEXT SELECTION HWC INP ERROR VALUE X to change to choose to save Definition This parameter selects the resulting output...

Страница 151: ...instrument configuration it may be necessary to disable one of the standard pens prior to activating one of the optional pens Only one function may be performed per color If all pens are in use an exi...

Страница 152: ...rammed the unit will automatically scroll to the next available function will return to the normal display or will continue to advance through the next parameter set Available parameters are STLR INP...

Страница 153: ...H DIVISION X to change to choose to save Definition This parameter determines the end of chart scale MUST REMAIN AT 100 TO ADVANCE TO NEXT SELECTION STLR INP ZONE LOW VALUE X to change to choose to sa...

Страница 154: ...e to choose to save Definition This parameter determines the frequency at which the scale information will be printed to the chart Example Range 120 220 Divisions set to 20 Chart scale 120 140 160 etc...

Страница 155: ...ext parameter defines the STLR SP tag that is printed on the chart scale TO ADVANCE TO NEXT SELECTION STLR SP DECIMAL POS X to change to choose to save Definition This parameter selects the decimal pl...

Страница 156: ...hoose to save Definition This parameter determines the start of chart scale value This value automatically tracks the STLR Input Event scale TO ADVANCE TO NEXT SELECTION STLR SP ZONE HIGH VALUE X to c...

Страница 157: ...EXT SELECTION STLR SP ERROR POSN DIVISIONS X to change to choose to save Definition This parameter determines where the pen will be positioned on an error condition TO ADVANCE TO NEXT SELECTION This c...

Страница 158: ...SFLR INP chart scale TO ADVANCE TO NEXT SELECTION SFLR INP ZONE LOW DIVISION X to change to choose to save Definition This parameter determines the start of chart scale MUST REMAIN AT 0 TO ADVANCE TO...

Страница 159: ...change to choose to save Definition This parameter determines the end of chart scale value Programmed per customer order in units matching either Flow or actual unit value received at 20 mA output sta...

Страница 160: ...ROR POSN DIVISIONS X to change to choose to save Definition This parameter determines where the pen will be positioned on an error condition TO ADVANCE TO NEXT SELECTION This completes SFLR INP pen se...

Страница 161: ...se to save Definition This parameter selects the decimal places for the CPRC INP chart scale TO ADVANCE TO NEXT SELECTION CPRC INP ZONE LOW DIVISION X to change to choose to save Definition This param...

Страница 162: ...C INP ZONE HIGH VALUE X to change to choose to save Definition This parameter determines the end of chart scale value TO ADVANCE TO NEXT SELECTION CPRC INP INTERVAL X DIVISIONS to change to choose to...

Страница 163: ...r set 7 6 Configuration Menu Chart Messages 7 6 1 Chart Messages Shunt Position RUN MODE No programming access is allowed under the RUN mode 7 6 2 Chart Messages Shunt Position PROGRAM MODE Consult fa...

Страница 164: ...NOT ALTER SETTINGS FOR DERIVED ACTUATORS 7 10 Configuration Menu LED s 7 10 1 LED s Shunt Position RUN MODE No programming access is allowed under the RUN mode 7 10 2 LED s Shunt Position PROGRAM MODE...

Страница 165: ...LR ALARM 1 SFLR ALARM 2 CPR ALARM 1 CPR ALARM 2 HWC ALARM 1 HWC ALARM 2 CHART RUN STATE DATA COLLECT STATE CONTROL ON STATE FWD FLOW ENABLED FWD FLOW REQUESTED STLR INPUT MISMATCH STLR OUT STLR ERR SF...

Страница 166: ...gramming access is allowed under the RUN mode 7 11 2 Relays Shunt Position PROGRAM MODE Note Refer to General Instrument Operations section for instructions on identifying RUN and PROGRAM mode of oper...

Страница 167: ...CPR ALARM 1 CPR ALARM 2 HWC ALARM 1 HWC ALARM 2 CHART RUN STATE DATA COLLECT STATE CONTROL ON STATE FWD FLOW ENABLED FWD FLOW REQUESTED STLR INPUT MISMATCH STLR OUT STLR ERR SFLR OUT SFLR ERR CPRC OU...

Страница 168: ...elay 1 programmed to SFLR Alarm 1 Relay 2 programmed to SFLR Alarm 2 DO NOT MODIFY this setting Wiring for Legal Flow Meter Based Timing system is connected to normally open contacts of both relays Th...

Страница 169: ...Instrument Operations section for instructions on identifying RUN and PROGRAM mode of operation From the Normal Display key until the following is visible SELECT TESTS With TESTS shown in the lower d...

Страница 170: ...CAL ED INPUT VALUES FACTORY USE ONLY mA OUTPUTS Verify mA output is functional Follow individual system prompts to initiate and complete desired test Revision 3 0 Section 8 2...

Страница 171: ...llows Note Refer to General Instrument Operations section for instructions on identifying RUN and PROGRAM mode of operation From the Normal Display key until the following is visible SELECT CALIBRATIO...

Страница 172: ......

Страница 173: ...evision Shunt Position RUN MODE PROGRAM MODE From the Normal Display key until the following is visible SELECT MODEL AND REVISION With MODEL AND REVISION shown in the lower display line key to view Mo...

Страница 174: ......

Страница 175: ...tion Definition This parameter is used as an identification tag It appears on the outside edge of the chart TO ADVANCE TO NEXT SELECTION CHART SPEED 6 HOURS 8 HOURS 12 HOURS 24 HOURS NOTE The U S Past...

Страница 176: ...or per hour TO ADVANCE TO NEXT SELECTION MINOR TIME PERIODS XX NOTE If unit has been programmed at the Factory for a Pasteurized Milk Ordinance regulated product this parameter MUST remain at 4 Three...

Страница 177: ...line with the exception that NO scale information is printed to the chart TO ADVANCE TO NEXT SELECTION MAJOR LINE PEN COLOR MATCH SCALE COLOR SELECT A COLOR to change or to choose to save Definition T...

Страница 178: ...O NEXT SELECTION MINOR LINE PEN COLOR MATCH SCALE COLOR SELECT A COLOR to change or to choose to save Definition This parameter allows selection of the color for the Minor Time line printed to the cha...

Страница 179: ...ION TIME PEN COLOR BLUE GREEN RED BLACK to change or to choose to save Definition This parameter allows selection of the color for the Time printed to the chart TO ADVANCE TO NEXT SELECTION evision 3...

Страница 180: ...GE LIST PRINT SCALES NOTE If unit has been programmed at the Factory for a Pasteurized Milk Ordinance regulated product this parameter MUST remain at NONE JUST CONTINUE to change or to choose to save...

Страница 181: ...ust be installed and maintained in accordance with Anderson instructions Users are responsible for the suitability of the products to their application There is no warranty against damage resulting fr...

Отзывы: