Installation and Setup
39
Instruction Manual – Enova DGX 8/16/32/64 Digital Media Switchers
Installation Options
Additional installation tasks may include the following:.
Establishing external serial control (DB-9 port) – page 60
Establishing external serial control (USB virtual COM port) – page 61
CPU backup with Micro SD memory card – page 66
Setting the Control Panel password – page 143
Defining local presets – page 196
Defining global presets – page 137
Attaching Cable Management Bars
If the enclosure has DXLink Fiber or Epica DGX SC Optical Input and Output Boards installed, cable management bars
are provided.
To install cable management bars:
1.
Enova DGX 32 only
– Loosen the two captive screws that hold the connector numbering plate at the top of the
connectors. Remove the connector numbering plate and set aside.
2.
Align the two screw holes on the end of the cable management bar with the two screw holes on the end of the board.
(Note the position of the long part of the bar in relation to screw holes.)
3.
Insert and tighten the two screws at the end of the cable management bar (do
not
over tighten the screws).
4.
Align, insert, and tighten the single screw at the other end of the cable management bar (do
not
over tighten).
5.
Tie the cable to the cable management bar far enough from the connector to allow for the manufacturer’s
recommended bend radius.
6.
Enova DGX 32 only
– Replace the connector numbering plate that was removed in Step 1.
Caution:
Do not severely bend or kink any type of fiber cable. Irreversible damage can occur. Refer to the
physical limitations (bend radius) specified for the cable by the manufacturer. The bend radius for AMX
SC terminated fiber cables is 2 inches (5 cm).
FIG. 17
Connector numbering plate on Enova DGX 32
FIG. 18
Installation of cable management bars
Connector numbering plate
Fasten cable management bar
with two screws on one end
and one on the other end
Tie cable to cable management
bar far enough from connector
to allow for manufacturer’s
recommended bend radius
Note:
On the Enova DGX 8/16/64, the orientation of the cable management bar is reversed from input to output board.
Input board
Output board
Enova DGX 32
Enova DGX 8/16/64
Important:
Do not over
tighten installation screws.
Note:
The bend radius for
AMX SC terminated fiber
cables is 2 inches (5 cm).