Epica DGX SC Optical Boards
118
Instruction Manual – Enova DGX 8/16/32/64 Digital Media Switchers
To connect SC fiber inputs and outputs:
1.
Recommended
–
Install the provided cable management bars (see page 39).
2.
Clean the fiber cable connector
–
Follow the manufacturer’s recommendations.
3.
Remove the protective cap from the SC fiber connector.
4.
Insert the fiber cable connector into the input and output SC fiber receptacles (FIG. 66).
5.
Tie the SC fiber cable to the cable management bar far enough below the connector to allow for the manufacturer’s
recommended bend radius. The bend radius for AMX SC terminated fiber cables is 2 inches (5 cm).
6.
Repeat the previous steps for the remaining fiber cables.
Note:
An SC Optical Board cannot work in conjunction with an Audio Insert/Extract Board that is located on
the same side of the enclosure as it is, i.e., the Audio Insert/Extract Board cannot insert or extract audio
directly onto or out of an SC Optical Board. However, SC Optical Boards can handle audio signals from or to
other types of boards that do work in conjunction with Audio Insert/Extract Boards. For example, if a video
signal with embedded audio is routed from an SC Optical input Board to an HDMI Output Board, the audio
can be extracted at the HDMI output, or if an audio signal is inserted onto an HDMI Input Board, the resulting
video with embedded audio signal can be routed through an SC Optical Output Board.
Important:
In the event that an HDCP protected signal is switched to an SC Optical Output Board, the image
will show as red and will not pass the image. This is a visual confirmation that the output does not support
HDCP protected content and as such has failed authentication with the Enova DGX Switcher. For HDCP
protected signals to display, we recommend the use of local output boards which support HDCP protected
source signals.
Caution:
CLASS 3R INVISIBLE LASER RADIATION WHEN OPEN; AVOID DIRECT EYE EXPOSURE.
FIG. 66
Fasten cables onto input and output connectors (shown with cable management bar)
Tie cable to cable management
bar far enough below connector
to allow for manufacturer’s
recommended bend radius
Enova DGX 32
Enova DGX 8/16/64