Wiring and Connections
19
Metreau Keypads
Wiring and Connections
Overview
Metreau keypads support both AxLink and SWT wiring configurations. Each is described in the
following sub-sections. For information on AxLink vs. SWT device addressing, refer to the
AxLink
Device Addressing
section on page 13.
AxLink Wiring
In AxLink mode, Metreau keypads use a standard four-pin captive-wire AxLink connector for power and
data.
MET-6SRC, MET-7 and MET-13 Rear Panel Components
FIG. 17 shows the basic rear components of the AxLink (MET-6N, MET-7 and MET-13) keypads:
Before touching the device, discharge the static electricity from your body by touching
a grounded metal object.
If using power from AxLink, disconnect the wiring from the control system before
wiring the Metreau keypad.
Do not connect power to the keypads until the wiring is complete.
Before touching the device, discharge the static electricity from your body by touching
a grounded metal object.
FIG. 17
MET-6SRC, MET-7 and MET-13 - Rear Components
not used
AxLink connector
(from NetLinx Controller)
Device Address
DIP Switch
not used
Mounting Plate