Page 2: ...NFORMATION First Publication Draft Document Release Only Updated fire zone information Second Publication Option Menu Navigation Updated Card Reader Interface Options Added Third Publication Slave Keypad Options Added Slave mode Zone Wiring Diagrams Added ...

Page 3: ...lay 10 DEVICE CONFIGURATION 11 Device Configuration Mode Access 11 Address Selection MENU 1 11 Device Options MENU 2 12 Device Default MENU 3 12 LOCAL INSTALLER LOGIN 12 Introduction 13 TIMING MENU 1 14 Entry Delay Timer MENU 1 1 14 Exit Delay Timer Menu 1 2 14 Alarm Siren Menu 1 3 15 Reader Pre Alarm Timer Menu 1 4 16 Reader Left Open Timer Menu 1 5 16 OPTIONS MENU 2 17 General Options Menu 2 1 1...

Page 4: ...CyberSuite condominium control keypad and installer programming functions Hardware Compatibility This manual is written for hardware verison 208 4125 020 or higher and covers firmware application 1 00 This firmware communicates with a CyberSuite enabled Protégé System Controller firmware version 1 06 or above ...

Page 5: ... be made in a daisy chain configuration avoiding star and stub connections Figure 1 Condominium Keypad Communication Keypad Wire Loom Colour Coding The condominium keypads are supplied with a wire loom attachment and are connected using a keyed 10 position snap lock connector The 10 way wiring loom connection uses the following colour coding Figure 2 Wire Loom Colour Coding and Function ...

Page 6: ...terface This interface is an isolated interface and requires power to be supplied to the N and N terminals Figure 3 Wire Loom Colour Coding and Function When using more than one PSU to supply multiple wiring runs of condominium keypads only connect the 12 output of ONE power supply unit to the N and N terminals of the controller Each PSU unit should have the common 0V or connected together to ensu...

Page 7: ...at are possible The programmed zone configuration for the CyberSuite LED Keypad is made in the option settings Refer to the General Options Section on Page 17 for the programming of the zone configuration When using a tamper input on a device the tamper contacts must be normally closed and wired in series All resistors required to wire the zone configurations are provided with the CyberSuite LED K...

Page 8: ...e Input Wiring Configuration on Page 4 Figure 7 Fire Smoke Detection Input When a fire zone is connected to a zone input that is used in the duplex zone configuration a fire zone fault will NOT BE shown when the fire zone has a shorted condition as this is shown as all zones closed A Fire Loop trouble will be shown when the zone is tampered Fire zones that are installed in duplex mode operation ar...

Page 9: ...Duplex mode enabled 8 zones in total available This setup is shown in Error Reference source not found Standard wiring mode 6 zones in total available This setup is shown in Figure 9 The choice between the two wiring options will be dependent on the physical configuration of the sensors and wiring in each installation See General Options on page 17 for enabling duplex zones Figure 8 Slave Keypad D...

Page 10: ...tput can be programmed to either Follow the status of the alarm siren time or the fire alarm setting Follow the armed disarmed status of the keypad Connect a relay or other interface device to this open collector output for activation of ancillary devices The behaviour of this output can also be inverted in the programming see the General Options section 0 for details on PGM programming Figure 10 ...

Page 11: ...Mount Proximity Card Reader Each slave reader device communicates with the keypad via a PRX SAM Standalone Module Board This module also allows control of an electronic lock device with the onboard relay Figure 11 Slave Reader Network Wiring To SAM Module For further information regarding wiring of the Reader device and the Stand Alone Modules please refer to the PRX SAM Stand Alone Module Install...

Page 12: ... in Slave Mode see Device Options for configuration Each slave reader device communicates with the keypad via connection of their primary network lines to the secondary network lines of the master keypad as shown below Note that the Slave Reader Network Enabled option must be OFF to allow use of the slave keypad network Figure 12 Slave Keypad Wiring to Master Keypad ...

Page 13: ...icator Lights Binary Number Display The CyberSuite LED keypad displays programming information such as timers and addresses using the 8 Zone LED s The Zone LED s will be lit in binary mode meaning that you must add the place value of each LED together to obtain the programmed value The place values are shown in the table below ZONE LED VALUE Zone 1 128 Zone 2 64 Zone 3 32 Zone 4 16 Zone 5 8 Zone 6...

Page 14: ...ard press the CLEAR key followed by the ENTER key The INSTALL LED will then be lit to notify that device configuration mode has been entered You can then press the key corresponding to the menu required from the following list Address Selection MENU 1 The address selection sets the address of the CyberSuite LED Keypad this address must be a unique address on the system from 1 to 250 Enter the addr...

Page 15: ... Keypad If this option is used be sure to address the keypad as slave 1 2 3 or 4 5 Enabled Slave mode is entered on start up 6 Disabled Master mode is entered on start up Option 2 to 8 Reserved Device Default MENU 3 To default all the Device Options press MENU 3 The ARMED LED will now flash and you must press ENTER to confirm or MENU to cancel Exiting Device Configuration Mode Once Device configur...

Page 16: ...ess If a module update has been performed on the system controller and the user code at system controller user location 3 UN00003 has been changed The code that is entered in this setting is now the local installer code This code is programmed system wide when an update is performed To disable the Installer Code on ALL CyberSuite keypads Recommended delete the code for User UN00003 by following th...

Page 17: ...ue press MENU 1 1 TIM 1 TIM 2 TIM 3 ENTER Where TIM 1 3 are the timer value digits entered using the 0 to 9 number keys Programming the entry delay timer to 0 will result in no entry delay operation for any zone that has been assigned the entry delay zone type Exit Delay Timer MENU 1 2 The exit timer is programmable from 000 to 255 seconds Default 30 Seconds To program the timer value press MENU 1...

Page 18: ... Alarm Siren MENU 1 3 The siren alarm timer is programmed from 000 to 250 minutes Default 4 minutes To program the timer value press MENU 1 3 TIM 1 TIM 2 TIM 3 ENTER Where TIM 1 3 are the timer value digits entered using the 0 to 9 number keys ...

Page 19: ...ds any number lower than 5 seconds entered will be automatically increased to 5 seconds to ensure correct reader operation Reader Left Open Timer MENU 1 5 The Reader Left Open Timer is programmable from 0 to 255 seconds Default 45 Seconds This is only used when the Reader Slave Network is enabled To program the timer value press MENU 1 5 TIM 1 TIM 2 TIM 3 ENTER Where TIM 1 3 are the timer value di...

Page 20: ...ration EOL or NO EOL EOL requires the use of 2 X 1K resistors to provide Short Alarm Closed and Tamper Monitoring NO EOL provides Alarm and Closed monitoring 5 Enabled EOL resistors are used 2R Mode 2 Zones 6 Disabled NO EOL resistors are used 2 Zones Option 2 Duplex Zone Operation If Option 2 is set Option 1 does not have any function When option 2 is set the zones will use a 1K and 2K4 resistor ...

Page 21: ...ve Communications Port will not be used Option 6 PGM Output Follows Alarm Status 5 Enabled the PGM Output will be enabled with the alarm siren time activation or fire alarm activation 6 Disabled the PGM Output will not change state regardless of the alarm status Option 7 PGM Output Follows Area Status 5 Enabled the PGM Output will be enabled when the CyberSuite system is armed and disabled when th...

Page 22: ... 6 Disabled FAST ARMING is disabled Option 2 Allow Fast Stay Arming 5 Enabled the system can be FAST STAY by pressing and holding the STAY key 6 Disabled FAST STAY arming is disabled Option 3 Allow Instant Arming During Stay Exit Delay 5 Enabled the system will allow the stay key to be pressed and held during the exit delay of a stay arming cycle to allow the stay arming to be changed to an instan...

Page 23: ...Enabled the CyberSuite keypad will send a message to the system controller when the system is armed or disarmed If this option is disabled the current status of the CyberSuite keypad will not be valid It is recommended this and the Report Alarm options are always enabled 6 Disabled no message will be sent Option 2 Report Alarms Fire and Normal 5 Enabled the CyberSuite keypad will send a message wh...

Page 24: ...staller Access 5 Enabled the system will report when the local installer code is used to gain access to the local installation options 6 Disabled no message will be sent when the installer access s the installer menu Option 7 Report Extended Information 5 Enabled the system will report extending information such as the device tamper and fire loop trouble conditions These conditions do not generate...

Page 25: ...the front desk when the 1 3 keys are held for a period of 2 seconds No message will be displayed on the screen or alarm generated 6 Disabled the 1 3 will not cause any alarm Option 2 4 6 Medical Alarm 5 Enabled the system will send a medical panic alarm to the front desk when the 4 6 keys are held for a period of 2 seconds No message will be displayed on the screen or alarm generated 6 Disabled th...

Page 26: ...stem will enable user code 8 to be a duress code user and on login will send a duress code to the central station or on site monitoring system 6 Disabled user code 8 will operate as a standard user Option 5 6 7 and 8 Reserved 5 Reserved 6 Reserved Do not modify the reserved options configuration ...

Page 27: ...ED corresponding to the current Zone Type being lit Zone Type Once you have selected a Zone you must select the Zone Type To select the Zone Type use the Ï and Ð keys to scroll through the available types and press the ENTER key to move to the next configuration menu for the selected zone You can also press the number button corresponding to the required zone type to instantly select that zone typ...

Page 28: ...tions The zone options select functions that relate to the operation of bypassing force arming and stay arming Once you have selected a Zone Type for your selected zone you must select the Zone Options To toggle options press the keys 1 to 8 and the corresponding Zone LED will be lit when that option is ENABLED Pressing the ENTER key will save the options Option 1 Bypass Allowed 5 Enabled the zone...

Page 29: ... to be armed A force armed zone will automatically be included in the alarm processing when the zone restores from the not ready condition 6 Disabled the zone is not able to be force armed Option 4 5 6 7 and 8 Reserved 5 Reserved 6 Reserved It is recommended not to enable disable or modify the settings of reserved options ...

Page 30: ...mes all feedback Please go to our website or use the information below Integrated Control Technology P O Box 302 340 Unit C North Harbour Post Centre 6 Ascension Place Auckland Mairangi Bay New Zealand Auckland New Zealand Phone 64 9 476 7124 Fax 64 9 476 7128 www integratedcontroltechnology com ...