AxLink Device Addressing
13
Metreau Keypads
AxLink Device Addressing
Overview
Metreau Keypads used in NetLinx applications require a unique numeric AxLink device address of 1-
255. Consider specifying the device address for each keypad before final installation.
Setting The AxLink Device Address
AxLink-enabled Metreau keypads (MET-6N, MET-7 and MET-13) use an eight-position mini-DIP
switch to specify a unique device address for each keypad in a NetLinx Control System (see FIG. 12).
1.
If connected, disconnect the power supply.
2.
Locate the 8-position mini-DIP switch on the rear panel.
3.
Set the DIP switch according to the values shown below.
AxLink device addressing applies only to the MET-6SRC, MET-7 and MET-13
keypads. Metreau Audio Keypads (DAS-MET-6SRC and DAS-MET-13) do not
require device addressing.
FIG. 12
DIP Switch and SWT Jumper locations
MET-6N
MET-7
DIP Switch
DIP Switch
DIP Switch
MET-13
Before touching the device, discharge the static electricity from your body by touching
a grounded metal object.
Switch
1 2 3 4 5
6
7
8
Value
1 2 4 8 16 32 64 128