Paradox DigiplexNE DGP2-641 Скачать руководство пользователя страница 1

LCD Keypad V1.1

DGP2-641

Reference and Installation Manual

Содержание DigiplexNE DGP2-641

Страница 1: ...LCD Keypad V1 1 DGP2 641 Reference and Installation Manual...

Страница 2: ......

Страница 3: ...ng Mode 6 Programming Methods 7 Feature Select Programming 7 Decimal Programming 7 Module Broadcast 7 Memory Key 8 Download Contents of Memory Key to Keypad 8 Copy the Keypad Contents to the Memory Ke...

Страница 4: ...losure 15 Beep on Trouble 15 Keypad Tamper Enable 16 Communication Bus Voltmeter 16 Programmable Output Options 18 PGM State 18 PGM Deactivation Mode 18 PGM Base Time 19 PGM Override 19 PGM Timer 19 P...

Страница 5: ...the touch of a button Since all programm ing is accomplished through the keypad please read this manual carefully 1 1 Specifications Power input 12 to 16 Vdc 80mA maximum PGM current limit 50 mA Numb...

Страница 6: ...as one traditional hardwired input terminal allowing you to connect one detector or door contact directly to the keypad For example a door contact located at the entry point of an establishment can be...

Страница 7: ...te i e a normally open PGM w ill close when a specific event has occurred in the system refer to section 5 0 on page 17 Upon activation the PGM can provide 50mA to any device connected to it If the cu...

Страница 8: ...oftware For more information refer to the WinLoad instructions or visit our Web site at www paradox ca 3 1 Entering Module Programming Mode The keypad like all other modules in the system is programme...

Страница 9: ...ed option and the digit will appear in the display This means the option is enabled Press the key again to remove the digit from the display thereby disabling the option Press E NTER when options are...

Страница 10: ...ey 3 4 Memory Key SECTIONS 510 AND 520 Download inform ation to and from an LCD keypad using the memory key PMC 3 Only the PMC 3 memory key will function with the LCD keypad 3 5 Download Contents of M...

Страница 11: ...onto the keypad s connector labelled KE Y refer to Figure 2 1 on page 5 Ensure that the write protect jumper is ON refer to Figure 3 1 2 To copy the contents to the memory key enter the keypad s progr...

Страница 12: ...001 options 5 to 8 can only be used if the keypad is connected to a DigiplexNE DGP NE96 control panel 4 2 Display Access Code Entry SECTION 003 OPT ION 1 The digits of the U ser Access Codes can be di...

Страница 13: ...2 and the AC and STATUS LED will be off until either a button is pressed or an access code is entered The period of time in which no action is performed is defined by the Confidential Mode Timer 005 2...

Страница 14: ...CD screen Figure 4 1 LCD Screen 4 6 Confidential Mode Timer SECTION 007 Section 007 determines the amount of time without action before the keypad enters Confidential Mode For more information on Conf...

Страница 15: ...will only em it the Confirmation Beep R ejection Beep and beep when a button is pressed 4 9 Beep on Exit Delay SECTION 004 OPT ION 2 The keypad can beep once every second during the Exit Delay Timer...

Страница 16: ...s have been sorted into groups With these options enabled the keypad will emit an intermittent beep tone whenever a trouble condition from the Trouble Groups occurs in the system The intermittent beep...

Страница 17: ...s location The readings w ill appear on the LC D screen A reading of 10 5V indicates that the voltage is too low This may occur when too many modules are connected to the bus a m odule is installed t...

Страница 18: ...g on the battery In some cases adding an external power supply may correct the situation 1 From Normal Mode press and hold the 0 key 2 Enter the INSTALLE R CODE by default 000000 3 Press ACC The volta...

Страница 19: ...M Activation Event occurs see section 5 6 the PGM will switch to its opposite state i e open to closed or closed to open The PGM can provide 50mA to any device connected to it 5 2 PGM Deactivation Mod...

Страница 20: ...n section 5 7 on page 19 page 19 and PGM Timers section section 5 5 on page 18 page 18 It will remain in its normal state until the PGM Override is disabled This option may be used to test the PGM con...

Страница 21: ...able in the Digiplex D igiplexNE Modules Programming Guide to program the keypad s PGM Activation Event Enter the sections that correspond to the E VE NT GRO UP FEATURE GROUP START and E ND of the PGM...

Страница 22: ...x DigiplexNE Modules Programming Guide to program the keypad s PGM Activation Event Enter the sections that correspond to the E VE NT GRO UP FEATURE GROUP START and E ND of the PGM and enter the requi...

Страница 23: ...messages can be programmed directly into the DigiplexNE control panel Refer to the DigiplexNE Reference Installation Manual and to the DigiplexN E Programming Guide for more details After entering the...

Страница 24: ...rrent cursor position ARM D elete U ntil the End Pressing the ARM key w ill delete all characters and spaces to the right of the cursor and at the cursor s position DISARM Numeric Keys Alphanumeric Ke...

Страница 25: ...ressed it w ill toggle the case setting from lower to upper case and vice versa ME M Special Characters After pressing the ME M key the cursor will turn into a flashing black square Using section 6 1...

Страница 26: ...24 Reference Installation Manual Table 6 1 Special Characters Catalog...

Страница 27: ...red by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this w arranty is expressly limited to repairing or replacing at Seller s option any...

Страница 28: ...26 Reference Installation Manual Notes...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...PRINTED IN CANADA 01 2003 DGP2641 EI08...